User's Manual
Performance Tests
Performance Verification
4Ć18
Trigger
Source CH1
b. Turn function generator output on.
c. Check that the oscilloĆ
scope displays a sine wave while the function generator gate signal
level is in upper portion of the display (see Figure 4Ć6).
Gate
Signal
Waveform
Output
CH2
CH1
Figure 4Ć6:ăRelationship between 1 Volt or Greater Gate Signal and
Waveform Output Signal
d. Push MODEPoĆ
larity to change the polarity to Negative.
e. Check that the
oscilloscope displays a sine wave while the function generator gate
signal level is in the lower portion of the display.
6. Turn the function generator output off and disconnect
the function generator.
Check Waveform Advance Mode
Electrical Characteristic Checked: Operating modes, Waveform AdĆ
vance, on pageĂ1Ć5.
Equipment Required: A 50ĂΩ coaxial cable and an oscilloscope.
Prerequisites: The AWG2005 meets the prerequisites listed on page 4Ć7.