User's Manual
6Ć33
1.
a. No tools are needed to do this procedure.
b. Locate the modules to be removed in the locator diagram,
, in Figure 6Ć4.
2. Set the AWG2005 with the bottom down on the work
surface and the left side facing you.
3.
a. Disconnect the ribbon interconnect cable from J3 of the power
supply module. See Figure 6Ć14.
b. As shown in Figure 6Ć14, slide (2) in the direction indicated by arrow
(1) while pushing it, and then remove the fan and fan frame.
c. Release the four hooks securing the fan, separate the fan and fan
frame.