User's Manual

Adjustment Procedures
5-20
AWG510 & AWG520 Service Manual
This procedure adjusts the level of the low-voltage power supply.
. Do this procedure only when replacing the low-voltage power supply unit.
Equipment
Required
  # $# #" # 
Adjust the voltage level: Adjust –5 V pod on the power supply unit so that
TP103 (VEE) on the A10/A11 Connector board is –4.60 V± 0.02 V.
See Figure 5–11.

 ! #!" !"
 ! #!" !"

  
Figure 5-11: Adjustment location for the power supply unit
LowĆVoltage Power