User Manual Color Printer Phaser 300X
A
Technical Notes
A-6
Phaser 300X Color Printer
Serial port
The printer’s serial port provides an RS-232 interface connection to PCs and
other hosts. The printer’s serial port has these built-in default settings.
■ Variable (factory default, Switch 7, down)
■ Baud rate — 9600
■ Flagging — Software (XON/XOFF)
■ Parity — None
■ Stop bits — 1
■ Data bits — 8
■ Check parity — False
■ Protocol — Normal
When Switch 7 on the printer’s rear panel is in the down position,
you can change the default setting. To change the serial port’s
settings, you can use the PostScript Level 2 setdevparams
command. Refer to the Phaser 300X Drivers and Utilities Printing
Reference for details.
■ Fixed (Switch 7, up)
■ Baud rate — 1200
■ Flagging — Software (XON/XOFF)
■ Parity — Space
■ Stop bits — 1
■ Data bits — 7
■ Check parity — False
■ Protocol — Normal