User Manual
Remote operation
*RST
Reset device
Syntax
*RST
Description
This command resets the unit configuration to default values (performs the
same action as Load Default Configuration m enu option on the front panel).
Allow at least three seconds after sending the *RST command before sending
further commands to allow all defaults to be processed and set.
*STB?
Read status byte
Syntax
*STB?
Returns 0 – 255
Description This command returns the value in the status byte.
:DSE
SetDataStatusEnableRegister
Syntax
:DSE <flags>
Where flags is the valu
e for enable register as a decimal 0 – 255
Default
255
Description
This command sets t
he bits in the Data Status Enable register that are
summarized by the DAS bit in the S tatus Byte.
:DSE?
Read Data Status Enable Register
Syntax
:
DSE?
Returns 0 – 255
Description
This command returns the value in the Data Status Enable register.
:DSR?
Read Data Status Register
Syntax
:DSR?
Returns 0 – 255
Description
This command returns the value in the Data Status register. The Data
Status Register is cleared once it has been read.
:DVC
Device clear
Syntax
:DVC
Description
This command has the same affect as
*RST or :CFG:U SER:LOAD 0
(loading the default user c onfiguration).
Allow at least three seconds after sending the *RST com
mand before sending
further commands to allow all defaults to be processed and set.
68 PA3000 Power Analyzer User Manual