User Manual

The menu system
Table 4 : Effects of frequency range settings in PWM mode (cont.)
Update rate
(seconds)
>10 Hz
<900 Hz 1 100 Hz 0.1 Hz 10 Hz
1.7 1.7 3.4 20.4
1.8 1.8 3.6 21.6
1.9 1.9 3.8 20.9
2.0 2.0 4.0 22.0
Results from channels not in PWM Motor mode will be returned at the specied
rate.
Inputs
The Inputs menu provides conguration options for all physical signal inputs of
the pow
er analyzer. Use this menu and the submenus to congure all wiring and
group settings. For normal operation, with the exception of the shunt selection, it
is not necessary to change these settings from the default values.
Wiring
For mu
ltiphase measurements, a number of c hannels can be assigned to a group
allowing precise frequency and phase analysis of the multiphase signals. The
frequency of the rst channel in the group is used as the fundamental frequency
for all channels in the group, and all phase measurements are relative to the phase
reference (voltage by default) of the rst channel in the group.
Below are gures showing how each channel would be connected for each
different wiring mode.
Figure 25: Single-phase, two-wire and DC measurements. Select 1 phase, 2 wire
mode
PA3000 Power Analyzer User Manual 47