:WRG
Wiring con
guration
Syntax :WRG:1P2 - Set 1 phase, 2 wire
:WRG:1P3 - Set 1 phase, 3 wire
:WRG:3P3 -S
et 3 phase, 3 wire
:WRG:3P4 - Set 3 phase, 4 wire
:WRG:3P3V3A - Set 3 phase, 3 wire (3V3A)
Description
This command sets up the wiring conguration for the group currently
selected
. Use the :INST:NSEL command rst to select the active group.
Syntax
:WRG?
Returns 0,1,2,3,or4
Each val
ue represents a wiring conguration:
0 is 1p2w
1 is 1p3w
2 is 3p3
w
3 is 3p4w
4 is 3p3w (3V3A)
:NAME
Group name
Syntax
:NAME <value>
Where <value> is the group name
Description
This command will set the display name for the group. The limit is eight
characters, per group name. Because this command works with a group,
use the :INST:NSEL command rst to select the active group.
Syntax
:NAME?
Returns
Group name up to eight characters
Description
This command will return the display name for the active group. Because
this command works with a group, use the :INST:NSEL command rst
to select the active group.