User Manual
Remote operation
Input setup commands
The input setup commands correspond to the Inputs menu. (See page 47, Inputs.)
They are used to control how signal inputs to the PA3000 are channelled and
controlled.
:WRG
Wiring confi
guration
Syntax :WRG:1P2 - Set 1 phase, 2 wire
:WRG:1P3 - Set 1 phase, 3 wire
:WRG:3P3 -S
et 3 phase, 3 wire
:WRG:3P4 - Set 3 phase, 4 wire
:WRG:3P3V3A - Set 3 phase, 3 wire (3V3A)
Description
This command sets up the wiring configuration for the group currently
selected
. Use the :INST:NSEL command first to select the active group.
Syntax
:WRG?
Returns 0,1,2,3,or4
Each val
ue represents a wiring configuration:
0 is 1p2w
1 is 1p3w
2 is 3p3
w
3 is 3p4w
4 is 3p3w (3V3A)
:NAME
Group name
Syntax
:NAME <value>
Where <value> is the group name
Description
This command will set the display name for the group. The limit is eight
characters, per group name. Because this command works with a group,
use the :INST:NSEL command first to select the active group.
Syntax
:NAME?
Returns
Group name up to eight characters
Description
This command will return the display name for the active group. Because
this command works with a group, use the :INST:NSEL command first
to select the active group.
PA3000 Power Analyzer User Manual 83