User Manual
Remote operation
Ballast mode (cont.)
Returns
Ballast frequency for the selected group
Description
This command returns the ballast frequency for the active group.
:MOD:SBY
Standby mode
Syntax
:MOD:SBY:PER <value >
Where <value> is the standby power integration period in the range of 1 to
1200 seconds as an integer
Description
This command will set the integration period for standby power mode.
(See page 43, Standby Power mode.) Because this command works with
a group, use the :INST:NSEL command fi rst to select the active group.
Syntax
:MOD:SBY:PER?
Returns
Integration period for the selected group
Description
This command returns the integration period for the active group.
:MOD:INT
Integrator mode
Synta
x
:MOD:INT:ST:METH <m ethod>
Where <method>
0 – manual
1–clock
2–level
Because the integrator is a group function, use the :INST:NSEL command
first to select the active group.
Description
This command sets the starting method for the integrator.
Syntax
:MOD:INT:ST:CLK:TIM E <time>
Where <time> is either hh:mm:ssA/P or hh:mm:ss
Description This command sets the integrator start time when used in clock start
method. The data in input is in the same format as the user has requested.
Syntax
:MOD:INT:ST:CLK:DAT E <date>
Where <date> is in one of the following formats:
dd:mm:yyyy or mm:dd:yyyy or yyyy:mm:dd
dd/mm/yyyy or mm/dd/yyyy or yyyy/mm/dd
dd-mm-yyyy or mm-dd-yyyy or yyyy-m m-dd
Description This command sets the integrator start date when used in clock start
method. The data in input is in the same format as the user has requested.
Syntax
:MOD:INT:ST:LVL:CH <channel>
Where <channel> is 1 through 4
80 PA3000 Power Analyzer User Manual