Table 5: Electrical characteristics (Cont.)
Characteristic Information
Maximum DC saturation 0.5 A
Signal Delay
5-foot probe with termination Approximat ely 9 ns
Insertion Im pedance 0.03 Ω or less at 1 MHz, i ncreasing to 1.0 Ω or less
at 60 MHz
Probe Rise Time ≤5.8 ns
Step Response Because the oscilloscope input capacitance becomes
a part of the termination network, the step response
will vary with different oscilloscopes
Aberrations (probe and termination
at either sensitivity setting.)
≤10% peak-to-peak within 50 ns of step; ≤2%
peak-to-peak thereafter
Table 6: Mechanical characteristics
Characteristic Information
Probe cable length 5ft 1.5 m
Net w eight:
Probe and 5-foot cable 3.60 oz ≈103 gm
Termination 1.7 oz ≈48 gm
Termination L3.47in
W1.10in
H0.86in
88 mm
28 mm
22 mm
Probe body L7.9in
W0.63in
H1.25in
200 mm
16 mm
32 mm