Instructions

Service Information
8
P6021 Instruction M anual
Table 3: Maximum ratings
Characteristic Information
Maximum c ontinuous (CW) current Refer t o Figure 3 for frequency derating curves
2mA/mV 5A
p-p
sine wave between 1.2 kHz and 5 MHz
10 mA/mV 15 A
p-p
sine wave between 300 Hz and 5 MHz
Maximum Pulse Current 250 A peak, not to exceed 500(A · s) or 5 A
RMS
.An
(A · s) product greater than 500(A · s) reduces
probe output to zero due to core saturation
Maximum working input voltage
(uninsulated conductors)
300 VAC or VDC, CAT I, and 600 V
pk
limited to
<10 ms and <25% duty factor.
100 MHz10 MHz1MHz1kHz100 Hz10 Hz
FREQUENCY
1A
0.1A
P-P
AMPS
10 A
20 A
100 A
10mA/mV
2mA/mV
Figure 3: Probe and termination input current vs. frequency derating