Datasheet

Data Sheet
Application Modules
Application modules have licenses which can be transferred between an application
module and an oscilloscope. The license may be contained in the module; allowing
the module to be moved from one instrument to another. Or, the license can be
contained in the oscilloscope; allowing the module to be removed and stored for
safekeeping. Transferring the license to an oscilloscope and removing the module
permits the use of more than 4 applications simultaneously.
Module Description
DPO4AERO Aerospace Serial Triggering and Analysis Module.
Enables triggering o n packet-level information on
MIL-STD-1553 buses as well as analytical tools
such as digital views of the signal, bus views, packet
decoding, search tools, and packet decode tables with
time-stamp informa tion.
Signal In puts Any Ch1 - Ch4, Math, Ref1 - Ref4
Recommended Probing Differential or single ended
(only one single-ended signal required)
DPO4AUDIO Audio Serial Triggering and Analysis Module. Enables
triggering on packet-level information on I
2
S, LJ, RJ,
and TDM audio buses as well as analytical tools
such as digital views of the signal, bus views, packet
decoding, search tools, and packet decode tables with
time-stamp informa tion.
Signal Inputs A ny Ch1 - Ch4, D0 - D15
Recommended Probing I
2
S, LJ, RJ, TDM: Single
ended
DPO4AUTO Automotive Serial Triggering and Analysis Module.
Enables triggering on packet-level information on CAN
and LIN buses as well as analytical tools such as
digital views of the signal, bus views, packet decoding,
search tools, and packet decode tables with time-stamp
information.
Signal Inputs LIN: Any Ch1 - Ch4, D0 - D15; CAN:
Any Ch1 - Ch4, (D0 - D15; single-ended probing only)
Recommended Probing LIN: Single ended; CAN:
Single ended or differential
DPO4AUTOMAX Extended Automotive Serial Triggering and Analysis
Module. Enables triggering on packet-level information
on CAN, LIN, and FlexRay buses as well as analytical
tools such as digital views of the signal, bus views,
packet decoding, search tools, packet decode tables
with time-stamp information, and eye d iagram a nalysis
software.
Signal Inputs LIN: Any Ch1 - Ch4, D0 - D15; CAN:
Any Ch1 - Ch4, (D0 - D15; single-ended probing only);
FlexRay: Any Ch1 - Ch4, (D0 - D15; single-ended
probing only)
Recommended Probing LIN: Single ended; CAN,
FlexRay: Single ended or differential
DPO4COMP Computer Serial Triggering and Analysis Mod ule.
Enables triggering o n packet-level information on
RS-232/422/485/UART buses as well as analytical
tools such as digital views of the signal, bus views,
packet decoding, search tools, and packet decode
tables with time-stamp information.
Signal Inputs Any Ch1 - Ch4, (D0 - D15;
single-ending probing only)
Recommended Probing RS-232/UART: Single ended;
RS-422/485: Differential
Module Description
DPO4EMBD Embedded Serial Triggering and Analysis Module.
Enables triggering on packet-level information on I
2
C
and SPI buses as well as analytical tools such as
digital views of the signal, bus views, packet decoding,
search tools, and packet decode tables with time-stamp
information.
Signal Inputs I
2
C: Any Ch1 - Ch4, D0 - D15; SPI: Any
Ch1 - Ch4, D0 - D15
Recommended Probing I
2
C, SPI: Single ended
DPO4ENET Ethernet Serial Triggering and Analysis Module.
Enables triggering on packet-level information on
10BASE-T and 100BASE-TX buses as well as
analytical tools such as digital views of the signal,
bus views, packet decoding, search tools, and packet
decode tables with time-stamp information.
Signal Inputs Any Ch1 - Ch4 for single-ended
probing; Any Ch1 - Ch4, Math, Ref1 - Ref4 for
differential probing
Recommended Probing 10BASE-T: Single ended or
differential; 100BASE-TX: Differential
DPO4USB USB Serial Triggering and Analysis Module. Enables
triggering on packet-level content for low-speed,
full-speed, and high-speed USB serial buses. Also
enables analytical tools such as digital views of the
signal, bus views, packet decoding, search tools, and
packet decode tables with time-stamp information for
low-speed, full-speed, and high-speed USB serial
buses.
Signal Inputs Low-speed and Full-speed: Any Ch1
- Ch4, (D0 - D15; for single-ending probing only);
Low-speed, Full-speed, and High-speed: Any Ch1 -
Ch4, Math, Ref1 - Ref4
Recommended Probing Low-speed and Full-speed:
Single ended or differential; High-speed: Differential
USB high-speed supported only on MDO4104-X
models
DPO4PWR
Power Analysis Application Module. Enables quick
and accurate analysis o f power quality, switching loss,
harmonics, safe operating area (SOA), modulation,
ripple, and slew rate (dI/dt, dV/dt)
DPO4LMT
Limit and Mask Testing Application Module. Enables
testing against limit templates generated from "golden"
waveforms and mask testing using custom or standard
telecommunications or compute r masks
DP
O4VID
HD
TV and Custom (nonstandard) Video Triggering
Mo
dule
MDO4TRIG
Advanced RF Power Level Triggering Module. Enables
thepowerlevelontheRFinputtobeusedasasource
in the following trigger type s: Pulse Width, Runt,
Timeout, Logic, and Sequence
18 www.tektronix.com