Datasheet
Data Sheet
Specifications
Characteristic MDO4054-3 MDO4104-3 MDO4054-6 MDO4104-6
Analog Channels
4
Bandwidth 500 MHz
1GHz
500 MHz
1GHz
Sample Rate (1-2 ch) 2.5 GS/s 5 GS/s 2.5 GS/s 5 GS/s
Sample Rate (3-4 ch) 2.5 GS/s
Digital Channels
16
RF Channels
1
Frequency Range
50 kHz - 3 GHz 50 kHz - 6 GHz
Real-time Capture Bandwidth ≥1GHz
Span 1 kHz - 3/6 GHz in a 1-2-5 sequence
Resolution Bandwidth 20 Hz - 10 MHz in a 1-2-3-5 sequence
Reference Level –140 dBm to +30 dBm in steps of 5 dBm
Vertical Scale 1 dB/div to 20 dB/div in a 1-2-5 sequence
Ver tical Position –10 divs to + 10 divs
Vertical Units dBm, dBmV, dBµV, dBµW, dBmA, dBµA
Displayed Average Noise
Level (DANL)
50 kHz - 5 MHz: < –130 dBm/Hz (< –134 dBm/Hz typical)
5MHz-3GHz: <–148dBm/Hz(<–152dBm/Hztypical)
3GHz-6GHz: <–140dBm/Hz(<–143dBm/Hztypical)
Spurious Response
2nd and 3rd Harmonic
Distortion (>30 MHz)
< –55 dBc (< –60 dBc typical)
2nd Order Intermodulation
Distortion
< –55 dBc (< –60 dBc typical)
3rd Order Intermodulation
Distortion
< –60 dBc (< –63 dBc typical)
Other A/D Spurs < –55 dBc (< –60 dBc typical)
Image and IF Rejection
< –50 dBc (< –55 dBc typical)
Residual Response < –78 dBm
Crosstalk to RF Channel from
Scope Channels
≤1 GHz input frequencies: < –68 dB from ref level
>1 GHz - 2 GHz input frequencies: < –48 dB from ref level
Phase Noise at 2 GHz CW 10 kHz: < –90 dBc/Hz, < –95 dBc/Hz (typical)
100 kHz: < –95 dBc/Hz, < –98 dBc/Hz (typical)
1 MHz: < –113 dBc/Hz, < –118 dBc/Hz (typical)
Level M easurement
Uncertainty (Input level
+10dBmto–50dBm)
20°C-30°C:<±1dB(<±0.5dBtypical)
Over operating range: < ±1.5 dB
Residual FM ≤100 Hz peak-to-peak in 100 ms
M
aximum Operating Input Level
Average Continuous Power +30 dBm (1 W)
DC Maximum Before
Damage
±40 V DC
Maximum Power Before
Damage (CW)
+33 dBm (2 W)
Maximum Power Before
Damage (Pulse)
+45dBm(32W)
(<10 µs pulse width, <1% duty cycle, and reference level of ≥ +10 dBm)
Power Level Trigger
Frequency Range
1MHz-3GHz 1MHz-6GHz
Amplitude Range +30 dBm to –40 dBm
Limits
With CF 1 MHz - 3.25 GHz: –35 dB from ref level
With CF >3.25 GHz: –15 dB from ref level
Minimum Pulse Duration
10 µs On Time with a minimum settling Off Time of 10 µs
RF to Analog Channel Skew
<5 ns
10 www.tektronix.com