Datasheet

www.tektronix.com 35
Mixed Domain Oscilloscopes
General Product Specifications
Display system
Display type 10.4 in. (264 mm) liquid-crystal TFT color display
Display resolution 1,024 horizontal × 768 vertical pixels (XGA)
Interpolation Sin(x)/x
Waveform styles Vectors, Dots, Variable Persistence, Infinite Persistence
Graticules Full, Grid, Solid, Cross Hair, Frame, IRE and mV
Format YT, XY, and simultaneous XY/YT
Maximum waveform capture rate
>340, 000 wfms/s in FastAcq acquisition mode on 1 GHz models
>270, 000 wfms/s in FastAcq acquisition mode on 200 MHz –500 MHz models
>50, 000 wfms/s in DPO acquisition mode on all models.
Input-output ports
USB 2.0 high-speed host port Supports USB mass storage devices and keyboard. Two ports on front and two ports on rear of instrument.
USB 2.0 device port Rear-panel connector allows for communication/control of oscilloscope through USBTMC or GPIB (with a
TEK-USB-488), anddirect printing to all PictBridge-compatible printers.
Printing Print PictBridge printer or to a printer that supports e-mail printing. Note: This product includes software devel-
oped by the OpenSSL Project for use in the OpenSSL Toolkit. (http://www.openssl.org/)
LAN port RJ-45 connector, supports 10/100/1000 Mb/s
Video out port DB-15 female connector, connect to show the oscilloscope display on an external monitor or projector. XGA
resolution.
Probe compensator output voltage and frequency
Front-panel pins
Amplitude 0 to 2.5 V
Frequency 1 kHz
Auxiliary out Rear-panel BNC connector
V
OUT
(Hi): 2.5 V open circuit, 1.0 V 50 Ω toground
V
OUT
(Lo): 0.7 V into a load of4 mA; 0.25 V 50 Ω to ground
Output can be configured to provide a pulse out signal when the oscilloscope triggers, the internal oscilloscope
reference clock out, or an event out for limit/mask testing.
External reference input Time-base system can phase lock to an external 10 MHz reference (10 MHz ±1%)
Kensington-style lock Rear-panel security slot connects to standard Kensington-style lock.
VESA mount Standard (MIS-D 100) 100 mm VESA mounting points on rear of instrument.
LAN eXtensions for Instrumentation (LXI)
Class LXI Core 2011
Version V1.4
Software
OpenChoice
®
Desktop Enables fast and easy communication between a Windows PC and your oscilloscope using USB or LAN. Transfer
and save settings, waveforms, measurements, and screen images. Included Word and Excel toolbars automate
the transfer of acquisition data and screen images from the oscilloscope into Word and Excel for quick reporting
or further analysis. Download from http://www.tek.com/downloads.
IVI driver Provides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/
CVI, MicrosoftNET, and MATLAB.