Datasheet

Video Picture Mode (optional)
Sources Channel 1, Channel 2, Channel 3, Channel 4
Video standards NTSC, PAL
Contrast and brightness Manual and automatic
Field selection Odd, Even, Interlaced
Picture location on screen Selectable X and Y location, width and height adjustment, start line and pixel and line-to-line offset control.
Power measurements (optional)
Power Quality Measurements V
RMS
, V
Crest Factor
, Frequency, I
RMS
, I
Crest Factor
, True Power, Apparent Power, Reactive Power, Power Factor, Phase Angle.
Switching loss measurements
Power loss T
on
, T
off
, Conduction, Total.
Energy loss T
on
, T
off
, Conduction, Total.
Harmonics THD-F, THD-R, RMS measurements. Graphical and table displays of harmonics. Test to IEC61000-3-2 Class A and MIL-
STD-1399, Section 300A.
Ripple measurements V
Ripple
and I
Ripple
.
Modulation Analysis Graphical display of +Pulse Width, –Pulse Width, Period, Frequency, +Duty Cycle, and –Duty Cycle modulation types.
Safe operating area Graphical display and mask testing of switching device safe operating area measurements.
dV/dt and dI/dt measurements Cursor measurements of slew rate.
Limit/Mask testing (optional)
Included standard masks
5
ITU-T, ANSI T1.102, USB
Test source Limit test: Any Ch1 - Ch4 or any R1 - R4
Mask test: Any Ch1 - Ch4
Mask creation Limit test vertical tolerance from 0 to 1 division in 1 m division increments; Limit test horizontal tolerance from 0 to 500 m division in
1 m division increments
Load standard mask from internal memory
Load custom mask from text file with up to 8 segments
Mask scaling Lock to Source ON (mask automatically re-scales with source-channel settings changes)
Lock to Source OFF (mask does not re-scale with source-channel settings changes)
Test criteria run until Minimum number of waveforms (from 1 to 1,000,000; Infinity)
Minimum elapsed time (from 1 second to 48 hours; Infinity)
Violation threshold From 1 to 1,000,000
Actions on test failure Stop acquisition, save screen image to file, save waveform to file, print screen image, trigger out pulse, set remote interface SRQ
5
≥350 MHz bandwidth models are recommended for mask testing on telecomm standards >55 Mb/s. 1 GHz bandwidth models are recommended for mask testing on high-speed (HS) USB.
Datasheet