Datasheet

P6616 MSO probe
This unique probe design offers two eight-channel pods. Each channel
ends with a probe tip featuring a recessed ground for simplified connection
to the device under test. The coax on the first channel of each pod is
colored blue making it easy to identify. The common ground uses an
automotive-style connector making it easy to create custom grounds for
connecting to the device under test. When connecting to square pins, the
P6616 has an adapter that attaches to the probe head extending the probe
ground flush with the probe tip so you can attach to a header. The P6616
offers outstanding electrical characteristics, having only 3 pF of capacitive
loading, a 100 kΩ input resistance, and is capable of acquiring toggle rates
>500 MHz and pulses as short as 1 ns in duration.
The P6616 MSO probe offers two eight-channel pods to simplify connecting to your
device.
Serial triggering and analysis (optional)
On a serial bus, a single signal often includes address, control, data, and
clock information. This can make isolating events of interest difficult.
Automatic trigger, decode, and search on bus events and conditions gives
you a robust set of tools for debugging serial buses. The optional serial
protocol triggering and analysis functionality is offered free for a 30-day trial
period. This free trial period starts automatically when the instrument is
powered on for the first time.
Triggering on a specific OUT Token packet on a USB full-speed serial bus. The yellow
waveform is the D+ and the blue waveform is the D-. A bus waveform provides decoded
packet content including Start, Sync, PID, Address, End Point, CRC, Data values, and
Stop.
Serial triggering
Trigger on packet content such as start of packet, specific addresses,
specific data content, unique identifiers, etc. on popular serial interfaces
such as I
2
C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/
UART, MIL-STD-1553, and I
2
S/LJ/RJ/TDM.
Bus display
Provides a higher-level, combined view of the individual signals (clock,
data, chip enable, etc.) that make up your bus, making it easy to identify
where packets begin and end and identifying sub-packet components such
as address, data, identifier, CRC, etc.
Mixed Signal Oscilloscopes — MSO4000B, DPO4000B Series
www.tek.com 7