User manual

Using the Menus
1760 Series Component Waveform/Vector Monitor User Manual
3-21
H A123 and B123 When COMPOSITE is se-
lected, the instruments internal reference is the
input channel currently selected for display. For
COMPONENT, the internal reference is A1 when A123
is selected, and B1 when B123 is selected (sync is
present only on the first channel).
VECTOR
H BARS The instrument can be configured to accept
75% or 100% amplitude color bar signals. Dual-
Standard instruments a llow color bar signal ampli-
tudes to be set for NTSC and for PAL operation.
H
SETUP (NTSC operation only) Configures t he
instrument to accept signals with or without setup.
H
PAL (PAL operation only) When +V is chosen,
the phase reference of the --V lines is inverted, then
shown as an ove rlay on the +V lines to provide a
comparison display. +V shows +V and --V on
alternate lines.
H
TEST Used by service pe rsonnel; refer to the
service manual.
FORMAT
H CONFIG—FORMAT is used to to select the configura-
tion of signal s used for interconnection of equi p-
ment. Ava ilable signal formats are:
GBR, SMPTE/
EBU
, BETA, and MII. When viewed as a waveform
parade display, GBR signals ma y be displayed in
either GBR sequence or RGB seque nce, as selected
through the
GBR PARADE GBR/RGB m enu.
Table 3-1 shows valid format sel ections.
H
CONFIG—FORMAT is also used to select which
display
(LIGHTNING or DIAMOND) is present when
the front-panel
LIGHTNING button is pressed.