User manual
Functional Overview
1760 Series Component Waveform/Vector Monitor User Manual
3-5
Displaying a Signal
Inputs
There are eight rear-pane l loop-through inputs, which may
eliminate the need for an external routing switcher. The in-
puts can be displayed singly or in combination.
Without
PARADE or OVERLAY selected, only one input selec-
tion can be made at a time. Each input channel button (in-
cluding
A123 / B123) toggles between A and B, and is
cancelled when a nother input button is pressed.
With
PARADE or OVERLAY selected, the input channels can be
displayed in com bination. Pushing an input channel button
sequences through t he l abeled channels, both, then off. Push-
ing another input button does not cancel the current selec-
tion, but adds to it. To return to “single input” operation,
push the
PARADE/OVERLAY button until it is off (LED is no
longer lighted).
A123 / B123
Selecting A123 provides a side-by-side display of the CH-A1,
CH-A2,
and CH-A3 inputs (B123 displays the CH-B1, CH-B2, and
CH-B3 inputs). This is designed for monitoring component
signals.
Parade
Selecting PARADE displays the input channels last sele cted
for
PARADE, allowing a custom configuration of inputs. In
PARADE mode, the LINE/FIELD button offers only two choices:
one line and one field.
PARADE allows up to four channels to be displayed side-by-
side. Additional channels will be overlaid.