User manual

At A Glance
1760 Series Component Waveform/Vector Monitor User Manual
2-6
H Without PARADE or OVERLAY selected, onl y one input
selection can be made at a time. Each input channel
button (including
A123 / B123) toggles between A
and B, and is ca ncelled when another input button is
pressed.
H With
PARADE or OVERLAY selected, multiple input
selections can be made; input buttons select
A, B,
both, or off, a nd do not cancel each other.
H Selecting
A123 provides a side-by-side display of the
CH-A1, CH-A2, and CH-A3 inputs (B123 displays the
CH-B1, CH-B2, and CH-B3 inputs). Selecting A123or
B123 turns off all other input channels. When
PARADE or OVERLAY is selected, A123 and B123 can
be displayed toge ther and in combination with othe r
inputs.
H
PARADE displays up to four input channels side-by-
side, with any additi onal inputs overlaid. Selec ting
PARADE displays the input channel(s) last selected
for
PARADE, allowing a custom configuration of
inputs. In
PARADE mode, the LINE/FIELD button
offers only two choices: one line and one field.
H
OVERLAY provides an overlaid display of all se-
lected inputs.
MENU
Push the desired menu button to enter that menu and enable
the associated functions. Push the button again to exit the
menu and disable the function. Refer t o page 3-7 for more
information about using menus.
H
FILTER allows choice of flat or filtered display of the
waveform signal.
H
CURSOR enables timing cursors, voltage cursors,
vector cursors and markers.
H
LIN SEL allows the selection of a single line or group
of lines for display.