User's Manual
Table Of Contents
- Title page
- Table of Contents
- General Safety Summary
- Preface
- Getting Started
- Operating Basics
- Reference
- Reference
- Menu Structures
- The Setup Menu Screen
- The Graphical Waveform Editor
- The Pattern Editor
- Quick Editing
- The Table Editor
- The Equation Editor
- The Sequence Editor
- The APPL Menu
- The UTILITY Window
- External Keyboards
- Setting General Purpose Knob Direction
- Formatting a Floppy Disk
- Displaying Disk Usage
- Screen Display Enable/Disable
- Focused Color
- Displaying Instrument Status
- Internal Clock (Date and Time)
- Resetting the Instrument
- Connecting to a GPIB Network
- Ethernet Networking
- Hardcopy
- Calibration and Diagnostics
- Upgrading the System Software
- Capturing Waveforms
- Waveform Programming Language
- Command Descriptions
- Programming Examples
- File Conversion
- File Management
- FG Mode
- Waveform Mixing Mode
- Synchronous Operation Mode (AWG710B only)
- Appendices
- Appendix A: Specifications (AWG710B)
- Appendix A: Specifications (AWG710)
- Appendix B: Performance Verification (AWG710B)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- External Clock Input and VCO Out Output Tests
- VCO OUT Output Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Synchronous Operation Tests
- Appendix B: Performance Verification (AWG710)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- 1/4 Clock Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Appendix C: Inspection and Cleaning
- Appendix D: Sample Waveforms
- Appendix E: File Transfer Interface Outline
- Appendix F: Miscellaneous
- Appendix G: Sequence File Text Format
- Index

Appendix B: Performance Verification (AWG710)
AWG710&AWG710B Arbitrary Waveform Generator User Manual B-61
Prerequisites
The tests in this section comprise an extensive, valid confirmation of performance
and functionality when the following requirements are met:
The cabinet must be installed on the instrument.
You must have performed and passed the procedures under Self Tests, found
on page B-56.
The waveform generator must have been recently adjusted at an ambient
temperature between +20° C and +30° C, must have been operating for a
warm–up period of at least 20 minutes, and must be operating at an ambient
temperature between +10° C and +40° C.
Refer to Conventions on page B-55 for more information.
Equipment Required
These procedures use external, traceable signal sources to directly check warranted
characteristics. Table B-5 lists the required equipment used to complete the
performance tests.
Table B-5: Test equipment
Item number and
description Minimum requirements Example (recommended) Purpose
1. Frequency Counter 1 MHz to 100 MHz,
Accuracy: < 0.2 ppm
Anritsu MF1603A Checks reference input.
2. Digital multi meter DC volts range: 0.05 V to 10 V,
Accuracy: ±0.1 %
Fluke 8842A Measures voltage. Used in
multiple procedures.
3. Oscilloscope Bandwidth: > 500 MHz, 1 MΩ and
50 Ω inputs
Tektronix TDS784D Checks output signals. Used in
multiple procedures.
4. Oscilloscope Bandwidth: > 6 GHz,
Rise time: < 58.3 ps, 50 Ω input
Tektronix TDS820 Checks pulse response.
5. Function Generator Output voltage: -5 V to +5 V,
Frequency accuracy: < 0.01 %
Tektronix AFG310 Generates external input
signals. Used in multiple input
signal test procedures.
6. SMA Coaxial Cable
(2 required)
50 Ω, male to male SMA connectors Tektronix part number
174–1427–00
Signal interconnection
7. BNC Coaxial Cable
(3 required)
50 Ω, male to male BNC connectors Tektronix part number
012–0482–00
Signal interconnection
8. Adapter
(2 required)
SMA (male) to BNC (female), 50 Ω Tektronix part number
015–0554–00
Signal interconnection
9. Adapter SMA (female) to BNC (male), 50 Ω Tektronix part number
015–0572–00
Signal interconnection
10. BNC–T Connector BNC (male) to BNC (female) to BNC
(female)
Tektronix part number
103–0030–00
Signal interconnection
11. Dual–Banana Connector BNC (female) to dual banana Tektronix part number
103–0090–00
Signal interconnection