User's Manual
Table Of Contents
- Title page
- Table of Contents
- General Safety Summary
- Preface
- Getting Started
- Operating Basics
- Reference
- Reference
- Menu Structures
- The Setup Menu Screen
- The Graphical Waveform Editor
- The Pattern Editor
- Quick Editing
- The Table Editor
- The Equation Editor
- The Sequence Editor
- The APPL Menu
- The UTILITY Window
- External Keyboards
- Setting General Purpose Knob Direction
- Formatting a Floppy Disk
- Displaying Disk Usage
- Screen Display Enable/Disable
- Focused Color
- Displaying Instrument Status
- Internal Clock (Date and Time)
- Resetting the Instrument
- Connecting to a GPIB Network
- Ethernet Networking
- Hardcopy
- Calibration and Diagnostics
- Upgrading the System Software
- Capturing Waveforms
- Waveform Programming Language
- Command Descriptions
- Programming Examples
- File Conversion
- File Management
- FG Mode
- Waveform Mixing Mode
- Synchronous Operation Mode (AWG710B only)
- Appendices
- Appendix A: Specifications (AWG710B)
- Appendix A: Specifications (AWG710)
- Appendix B: Performance Verification (AWG710B)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- External Clock Input and VCO Out Output Tests
- VCO OUT Output Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Synchronous Operation Tests
- Appendix B: Performance Verification (AWG710)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- 1/4 Clock Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Appendix C: Inspection and Cleaning
- Appendix D: Sample Waveforms
- Appendix E: File Transfer Interface Outline
- Appendix F: Miscellaneous
- Appendix G: Sequence File Text Format
- Index

Appendix A: Specifications (AWG710)
A-40 AWG710&AWG710B Arbitrary Waveform Generator User Manual
Certification and Compliances
The certification and compliances for the AWG710 Arbitrary Waveform Generator
are listed in Table A-50.
Table A-50: Certifications and compliances
Characteristics Description
EC declaration of conformity
EC council EMC Directive 89/336/EEC, amended by 89/336/EEC; EN61326-1: 1997 Product
Family Standard for Electrical Equipment for Measurement, Control, and Laboratory
Use-EMC Requirements.
Emissions:
EN 55011 Class A
EN 61000–3–2
Radiated and Conducted emissions
Power Line Harmonic
Immunity:
EN 61000–4–2
EN 61000–4–3
EN 61000–4–4
6
EN 61000–4–5
EN 61000–4–6
EN 61000–4–11
Electrostatic Discharge Immunity
Radiated RF Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
Conducted Disturbances Induced by RF Field Immunity
Power Line Interruption Immunity
Compliance was demonstrated to the following specification as listed in the Official Journal of
the European Communities:
Low Voltage Directive 73/23/EEC, amended by 93/68/EEC
EN 61010–1/A2:1995 Safety requirements for electrical equipment for measurement,
control, and laboratory use
Australia/New Zealand declaration of
conformity - EMC
Conforms with the following standards in accordance with the Electromagnetic Compatibility
Framework:
AS/NZS 2064.1/2
Class A radiated and Conducted Emissions
Safety UL3111–1 - Standard for electrical measuring and test equipment
Third party certification
CAN/CSA C22.2 No. 1010.1 - Safety requirements for electrical equipment for measurement,
control and laboratory use
Self declaration IEC 61010–1/A2:1995 - Safety requirements for electrical equipment for measurement,
control, and laboratory use
Installation category
Power input — Installation Category II (as defined in IEC 61010–1, Annex J)
Pollution degree
Pollution Degree 2 (as defined in IEC 61010–1)
6
Up to 200 mV
p–p