User's Manual
Table Of Contents
- Title page
- Table of Contents
- General Safety Summary
- Preface
- Getting Started
- Operating Basics
- Reference
- Reference
- Menu Structures
- The Setup Menu Screen
- The Graphical Waveform Editor
- The Pattern Editor
- Quick Editing
- The Table Editor
- The Equation Editor
- The Sequence Editor
- The APPL Menu
- The UTILITY Window
- External Keyboards
- Setting General Purpose Knob Direction
- Formatting a Floppy Disk
- Displaying Disk Usage
- Screen Display Enable/Disable
- Focused Color
- Displaying Instrument Status
- Internal Clock (Date and Time)
- Resetting the Instrument
- Connecting to a GPIB Network
- Ethernet Networking
- Hardcopy
- Calibration and Diagnostics
- Upgrading the System Software
- Capturing Waveforms
- Waveform Programming Language
- Command Descriptions
- Programming Examples
- File Conversion
- File Management
- FG Mode
- Waveform Mixing Mode
- Synchronous Operation Mode (AWG710B only)
- Appendices
- Appendix A: Specifications (AWG710B)
- Appendix A: Specifications (AWG710)
- Appendix B: Performance Verification (AWG710B)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- External Clock Input and VCO Out Output Tests
- VCO OUT Output Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Synchronous Operation Tests
- Appendix B: Performance Verification (AWG710)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- 1/4 Clock Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Appendix C: Inspection and Cleaning
- Appendix D: Sample Waveforms
- Appendix E: File Transfer Interface Outline
- Appendix F: Miscellaneous
- Appendix G: Sequence File Text Format
- Index

Appendix A: Specifications (AWG710B)
AWG710&AWG710B Arbitrary Waveform Generator User Manual A-25
Certification and Compliances
The certification and compliances for the AWG710B Arbitrary Waveform
Generator are listed in Table A-28.
Table A-28: Certifications and compliances
Characteristics Description
EC declaration of conformity
EC council EMC Directive 89/336/EEC, amended by 89/336/EEC; EN61326-1: 1997 Product
Family Standard for Electrical Equipment for Measurement, Control, and Laboratory
Use-EMC Requirements.
Emissions:
EN 55011 Class A
EN 61000–3–2
EN 61000–3–3
Radiated and Conducted emissions
Power Line Harmonic
Line voltage alteration and flicker
Immunity:
EN50082–1
EN 61000–4–2
EN 61000–4–3
EN 61000–4–5
EN 61000–4–6
EN 61000–4–4
6
EN 61000–4–8
EN 61000–4–11
Electrostatic Discharge Immunity
Radiated RF Electromagnetic Field Immunity
Surge Immunity
Conducted Disturbances Induced by RF Field Immunity
Electrical Fast Transient/Burst Immunity
Power Frequency Electromagnetic
Power Line Interruption Immunity
Compliance was demonstrated to the following specification as listed in the Official Journal of
the European Communities:
Low Voltage Directive 73/23/EEC, amended by 93/68/EEC
EN 61010–1/A2:1995 Safety requirements for electrical equipment for measurement,
control, and laboratory use
Australia/New Zealand declaration of
conformity - EMC
Conforms with the following standards in accordance with the Electromagnetic Compatibility
Framework:
AS/NZS 2064.1/2
Class A radiated and Conducted Emissions
Safety UL3111–1 - Standard for electrical measuring and test equipment
Third party certification
CAN/CSA C22.2 No. 1010.1 - Safety requirements for electrical equipment for measurement,
control and laboratory use
Self declaration IEC 61010–1/A2:1995 - Safety requirements for electrical equipment for measurement,
control, and laboratory use
Installation category
Power input — Installation Category II (as defined in IEC 61010–1, Annex J)