User's Manual
Table Of Contents
- Title page
- Table of Contents
- General Safety Summary
- Preface
- Getting Started
- Operating Basics
- Reference
- Reference
- Menu Structures
- The Setup Menu Screen
- The Graphical Waveform Editor
- The Pattern Editor
- Quick Editing
- The Table Editor
- The Equation Editor
- The Sequence Editor
- The APPL Menu
- The UTILITY Window
- External Keyboards
- Setting General Purpose Knob Direction
- Formatting a Floppy Disk
- Displaying Disk Usage
- Screen Display Enable/Disable
- Focused Color
- Displaying Instrument Status
- Internal Clock (Date and Time)
- Resetting the Instrument
- Connecting to a GPIB Network
- Ethernet Networking
- Hardcopy
- Calibration and Diagnostics
- Upgrading the System Software
- Capturing Waveforms
- Waveform Programming Language
- Command Descriptions
- Programming Examples
- File Conversion
- File Management
- FG Mode
- Waveform Mixing Mode
- Synchronous Operation Mode (AWG710B only)
- Appendices
- Appendix A: Specifications (AWG710B)
- Appendix A: Specifications (AWG710)
- Appendix B: Performance Verification (AWG710B)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- External Clock Input and VCO Out Output Tests
- VCO OUT Output Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Synchronous Operation Tests
- Appendix B: Performance Verification (AWG710)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- 1/4 Clock Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Appendix C: Inspection and Cleaning
- Appendix D: Sample Waveforms
- Appendix E: File Transfer Interface Outline
- Appendix F: Miscellaneous
- Appendix G: Sequence File Text Format
- Index

Synchronous Operation Mode (AWG710B only)
AWG710&AWG710B Arbitrary Waveform Generator User Manual 3-255
Connection with Slave
Connection and disconnection with Slave are performed by Master using the
Connect to Slave and Disconnect menu.
1. Push SETUP (front-panel)!Connect(bottom) !Connect to Slave (side)
button to connect to the slave AWG710B.
2. Push SETUP (front-panel)!Connect(bottom) !Disconnect (side) button to
disconnect to the slave AWG710B.
In the following cases, the connection between Master and Slave is canceled
automatically.
The LAN cable is unplugged from the connector.
The power of Slave was turned off.
Master or Slave was changed from Synchronous Operation mode.
When executing Diagnostic or Calibration of the UTILITY menu.
Error messages on connection
When making connection with Slave in Synchronous Operation mode, the
AWG710B is also performing Trigger Timing CAL automatically.
The following error/warning messages may be displayed during operation in
Synchronous Operation mode.
Table 3-59: Error/Warning messages
Message Description
Gated is not available in Synchronous Operation.Run
Mode will be changed to Continuous.
It is the warning message which comes out when it is going to go into
Sync-Master, where Gated is specified by Run Mode. Ruined switches to
Continuous.
External Clock Source or External Clock Reference is not
available in Synchronous Operation - Slave. Clock Source
and Clock Reference will be changed to Internal
It is the warning message which comes out when it is going to go into
Sync-Slave, where External is specified by ClockSource or by
ClockReference. As for the Slave itself, Clock and Reference Clock operate in
the state of Internal.
Connection will be lost. It is displayed, when connection between Master and Slave is established and
it is going to perform Calibration/Diagnostics of the UTILITY menu.