User's Manual
Table Of Contents
- Title page
- Table of Contents
- General Safety Summary
- Preface
- Getting Started
- Operating Basics
- Reference
- Reference
- Menu Structures
- The Setup Menu Screen
- The Graphical Waveform Editor
- The Pattern Editor
- Quick Editing
- The Table Editor
- The Equation Editor
- The Sequence Editor
- The APPL Menu
- The UTILITY Window
- External Keyboards
- Setting General Purpose Knob Direction
- Formatting a Floppy Disk
- Displaying Disk Usage
- Screen Display Enable/Disable
- Focused Color
- Displaying Instrument Status
- Internal Clock (Date and Time)
- Resetting the Instrument
- Connecting to a GPIB Network
- Ethernet Networking
- Hardcopy
- Calibration and Diagnostics
- Upgrading the System Software
- Capturing Waveforms
- Waveform Programming Language
- Command Descriptions
- Programming Examples
- File Conversion
- File Management
- FG Mode
- Waveform Mixing Mode
- Synchronous Operation Mode (AWG710B only)
- Appendices
- Appendix A: Specifications (AWG710B)
- Appendix A: Specifications (AWG710)
- Appendix B: Performance Verification (AWG710B)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- External Clock Input and VCO Out Output Tests
- VCO OUT Output Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Synchronous Operation Tests
- Appendix B: Performance Verification (AWG710)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- 1/4 Clock Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Appendix C: Inspection and Cleaning
- Appendix D: Sample Waveforms
- Appendix E: File Transfer Interface Outline
- Appendix F: Miscellaneous
- Appendix G: Sequence File Text Format
- Index

Waveform Mixing Mode
3-246 AWG710&AWG710B Arbitrary Waveform Generator User Manual
B is small, it repeats until it becomes the number of points of a mixed
waveform.
Same as B: The number of points of a mixed waveform is made the same as
the number of points of Waveform B. When the number of points of Waveform
A is small, it repeats until it becomes the number of points of a mixed
waveform.
LCM(A,B): The number of points of a mixed waveform is made into the least
common multiple of the number of points of two waveforms.
1. Push Waveform/Sequence (bottom)!Setting... (side)!Wfm Len(side)
2. Use the general purpose knob or Wfm Len menu button to select the length of
a mixed waveform.
Update
Loading of the file in AWG mode sets data to the waveform memory for a
waveform output. On the other hand, loading of the file in Waveform Mixing mode
sets data to the work area for waveform mixing. When data is set to Waveform A
and Waveform B, preparation of waveform mixing will be completed. Based on
parameters of waveform mixing, a mixed waveform is generated in a work area,
and a mixed waveform is outputted in loading to a waveform memory.
With the Update button, you can specify the timing which generates a mixed
waveform and is loaded to a waveform memory.
Auto: When the file of Waveforms A or B is changed, or when a waveform
mixing parameter is changed, a mixed waveform is regenerated and waveform
data is loaded to a waveform memory.
Manual: When the Update Waveform button (it will become effective if
Manual is selected) is pushed, a mixed waveform data is regenerated and it is
loaded to a waveform memory.
It takes much time in order to generate a large mixed waveform. By choosing
Manual, it can prevent regenerating a mixed waveform at every parameter change.
1. Push Waveform/Sequence (bottom)!Update (side)
2. Push the Update side button to toggle between Auto and Manual.
When Manual is selected, the Update Waveform side button becomes effective.