User's Manual
Table Of Contents
- Title page
- Table of Contents
- General Safety Summary
- Preface
- Getting Started
- Operating Basics
- Reference
- Reference
- Menu Structures
- The Setup Menu Screen
- The Graphical Waveform Editor
- The Pattern Editor
- Quick Editing
- The Table Editor
- The Equation Editor
- The Sequence Editor
- The APPL Menu
- The UTILITY Window
- External Keyboards
- Setting General Purpose Knob Direction
- Formatting a Floppy Disk
- Displaying Disk Usage
- Screen Display Enable/Disable
- Focused Color
- Displaying Instrument Status
- Internal Clock (Date and Time)
- Resetting the Instrument
- Connecting to a GPIB Network
- Ethernet Networking
- Hardcopy
- Calibration and Diagnostics
- Upgrading the System Software
- Capturing Waveforms
- Waveform Programming Language
- Command Descriptions
- Programming Examples
- File Conversion
- File Management
- FG Mode
- Waveform Mixing Mode
- Synchronous Operation Mode (AWG710B only)
- Appendices
- Appendix A: Specifications (AWG710B)
- Appendix A: Specifications (AWG710)
- Appendix B: Performance Verification (AWG710B)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- External Clock Input and VCO Out Output Tests
- VCO OUT Output Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Synchronous Operation Tests
- Appendix B: Performance Verification (AWG710)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- 1/4 Clock Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Appendix C: Inspection and Cleaning
- Appendix D: Sample Waveforms
- Appendix E: File Transfer Interface Outline
- Appendix F: Miscellaneous
- Appendix G: Sequence File Text Format
- Index

File Management
AWG710&AWG710B Arbitrary Waveform Generator User Manual 3-231
When you display the double windows, the Select side button will be available.
Push the Select side button to select Upper for file operation in the upper file list
window. Push the Select side button again to select Lower for file operation in the
lower file list window.
Operation in Double
Windows
The most useful functions to be used in the double windows may be those invoked
from the File bottom button. The functions available in the File bottom button are
described in Table 3-52.
In copy or move operation, when the files with the same file name exist in the
destination, the message Overwrite existing file? appears. At the same time, the
Cancel, No, Yes to All, and Ye s side buttons appear. Press any of these side
buttons to proceed.
Table 3-52: File operation in double windows
Operation Description
Copy Copies a file from a selected file list window into the destination specified
in the other file list window.
You cannot select the directory.
Copy All Copies all files in a selected file list window into the destination specified in
the other file list window.
You cannot copy the directory or directory structure.
Move Moves a file selected in a selected file list window into the destination
specified in the other file list window.
You cannot select the directory.
Move All Moves all files in a selected file list window into the destination specified in
the other file list window.
You cannot move the directory or directory structure.
NOTE. You cannot use the Rename, Delete, Delete All, and Attribute side buttons
unless you display the single file list window.