User's Manual
Table Of Contents
- Title page
- Table of Contents
- General Safety Summary
- Preface
- Getting Started
- Operating Basics
- Reference
- Reference
- Menu Structures
- The Setup Menu Screen
- The Graphical Waveform Editor
- The Pattern Editor
- Quick Editing
- The Table Editor
- The Equation Editor
- The Sequence Editor
- The APPL Menu
- The UTILITY Window
- External Keyboards
- Setting General Purpose Knob Direction
- Formatting a Floppy Disk
- Displaying Disk Usage
- Screen Display Enable/Disable
- Focused Color
- Displaying Instrument Status
- Internal Clock (Date and Time)
- Resetting the Instrument
- Connecting to a GPIB Network
- Ethernet Networking
- Hardcopy
- Calibration and Diagnostics
- Upgrading the System Software
- Capturing Waveforms
- Waveform Programming Language
- Command Descriptions
- Programming Examples
- File Conversion
- File Management
- FG Mode
- Waveform Mixing Mode
- Synchronous Operation Mode (AWG710B only)
- Appendices
- Appendix A: Specifications (AWG710B)
- Appendix A: Specifications (AWG710)
- Appendix B: Performance Verification (AWG710B)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- External Clock Input and VCO Out Output Tests
- VCO OUT Output Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Synchronous Operation Tests
- Appendix B: Performance Verification (AWG710)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- 1/4 Clock Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Appendix C: Inspection and Cleaning
- Appendix D: Sample Waveforms
- Appendix E: File Transfer Interface Outline
- Appendix F: Miscellaneous
- Appendix G: Sequence File Text Format
- Index

AWG710&AWG710B Arbitrary Waveform Generator User Manual 3-219
File Conversion
The AWG710&AWG710B Arbitrary Waveform Generator has the ability to
import and export various formats of waveform data. Import converts waveform
files created with other instruments into files the AWG710&AWG710B Arbitrary
Waveform Generator can use. Export converts AWG710&AWG710B Arbitrary
Waveform Generator waveform files into text files.
Each AWG710&AWG710B Arbitrary Waveform Generator waveform file
contains the clock rate information, waveform data, and marker information.
Import uses default values for the information unavailable through the external file.
Import
The following files can be converted into AWG710&AWG710B Arbitrary
Waveform Generator compatible waveform files:
AWG20xx.WFM to Waveform
An AWG2000 Series .wfm file is converted into an AWG710&AWG710B
Arbitrary Waveform Generator waveform file. The marker data and clock rates
are inherited.
AWG20xx.WFM to Pattern
An AWG2000 Series .wfm file is converted into an AWG710&AWG710B
Arbitrary Waveform Generator pattern file. The marker data and clock rates
are inherited.
Note that the upper 8 bits in the AWG2021 or AWG2005 waveform file are
converted into the AWG710&AWG710B Arbitrary Waveform Generator
waveform file. The lower four bits are neglected. In the AWG2041 waveform
file, 8–bit data is imported with no convention into the data bits: Data 0 to Data
7 in the AWG710&AWG710B Arbitrary Waveform Generator pattern file.
TDS.WFM to Waveform
A waveform file generated with a Tektronix TDS–Series oscilloscope is
converted into an AWG710&AWG710B Arbitrary Waveform Generator
waveform file. The clock rate and position information are inherited. The
offset information is neglected in this conversion.
The AWG710&AWG710B Arbitrary Waveform Generator is unable to
transfer waveforms during some oscilloscope acquisition modes such as Fast
Acquisition, for example. Contact Tektronix Technical support for more
information.