User's Manual
Table Of Contents
- Title page
- Table of Contents
- General Safety Summary
- Preface
- Getting Started
- Operating Basics
- Reference
- Reference
- Menu Structures
- The Setup Menu Screen
- The Graphical Waveform Editor
- The Pattern Editor
- Quick Editing
- The Table Editor
- The Equation Editor
- The Sequence Editor
- The APPL Menu
- The UTILITY Window
- External Keyboards
- Setting General Purpose Knob Direction
- Formatting a Floppy Disk
- Displaying Disk Usage
- Screen Display Enable/Disable
- Focused Color
- Displaying Instrument Status
- Internal Clock (Date and Time)
- Resetting the Instrument
- Connecting to a GPIB Network
- Ethernet Networking
- Hardcopy
- Calibration and Diagnostics
- Upgrading the System Software
- Capturing Waveforms
- Waveform Programming Language
- Command Descriptions
- Programming Examples
- File Conversion
- File Management
- FG Mode
- Waveform Mixing Mode
- Synchronous Operation Mode (AWG710B only)
- Appendices
- Appendix A: Specifications (AWG710B)
- Appendix A: Specifications (AWG710)
- Appendix B: Performance Verification (AWG710B)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- External Clock Input and VCO Out Output Tests
- VCO OUT Output Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Synchronous Operation Tests
- Appendix B: Performance Verification (AWG710)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- 1/4 Clock Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Appendix C: Inspection and Cleaning
- Appendix D: Sample Waveforms
- Appendix E: File Transfer Interface Outline
- Appendix F: Miscellaneous
- Appendix G: Sequence File Text Format
- Index

Command Descriptions
3-194 AWG710&AWG710B Arbitrary Waveform Generator User Manual
Delete( )
The delete() statement deletes the specified file name from the current drive.
Group
Waveform
Syntax
delete("filename")\
Arguments
"filename" is the complete file name (path, file name and extension) to the file
that you want to delete. The file must be located on the active drive. The argument
can include a relative or absolute path name. Enclose the file name within double
quotation marks.
Example
delete("/test_dir/wvfrms/sine2x.wfm")
Diff( )
The diff() statement performs a differentiation operation on a specified file. The
output file retains all marker values of the input file. Refer to Differentiation on
page F-1 for information about the differentiation algorithm.
Group
Waveform
Syntax
"output_filename" = diff("filename")
Arguments
"output_filename" is the complete file name (file name and extension) to
contain the resultant waveform. The argument can include a relative or absolute
path name. Enclose the file name within double quotation marks.
"filename" is the complete (file name and extension) name of the file on which
you are performing the differentiation operation. The file must be on the active
drive. The argument can include a relative or absolute path name. Enclose the file
name within double quotation marks.
Example
"diffwave.wfm" = diff("log_swp.wfm")