User's Manual
Table Of Contents
- Title page
- Table of Contents
- General Safety Summary
- Preface
- Getting Started
- Operating Basics
- Reference
- Reference
- Menu Structures
- The Setup Menu Screen
- The Graphical Waveform Editor
- The Pattern Editor
- Quick Editing
- The Table Editor
- The Equation Editor
- The Sequence Editor
- The APPL Menu
- The UTILITY Window
- External Keyboards
- Setting General Purpose Knob Direction
- Formatting a Floppy Disk
- Displaying Disk Usage
- Screen Display Enable/Disable
- Focused Color
- Displaying Instrument Status
- Internal Clock (Date and Time)
- Resetting the Instrument
- Connecting to a GPIB Network
- Ethernet Networking
- Hardcopy
- Calibration and Diagnostics
- Upgrading the System Software
- Capturing Waveforms
- Waveform Programming Language
- Command Descriptions
- Programming Examples
- File Conversion
- File Management
- FG Mode
- Waveform Mixing Mode
- Synchronous Operation Mode (AWG710B only)
- Appendices
- Appendix A: Specifications (AWG710B)
- Appendix A: Specifications (AWG710)
- Appendix B: Performance Verification (AWG710B)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- External Clock Input and VCO Out Output Tests
- VCO OUT Output Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Synchronous Operation Tests
- Appendix B: Performance Verification (AWG710)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- 1/4 Clock Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Appendix C: Inspection and Cleaning
- Appendix D: Sample Waveforms
- Appendix E: File Transfer Interface Outline
- Appendix F: Miscellaneous
- Appendix G: Sequence File Text Format
- Index

Quick Editing
AWG710&AWG710B Arbitrary Waveform Generator User Manual 3-101
When you cancel the changes and quit the quick editor, the instrument copies the
data in the undo buffer back to the edit buffer (and also to the waveform memory
if the data is being loaded), and then terminate the quick editor.
About Smoothing
Quick Edit performs expand, shrink, or shift the cursor–to–cursor data.
Consequently, if nothing is processed, a gap may be produced between the changed
and unchanged portions. To link the entire data smoothly, smoothing is performed.
Cursor–to–cursor points move in response to turning the general purpose knob.
Also for the unchanged portions, the smoothing moves the positions so that the
entire data is linked smoothly. This occurs throughout the range specified with the
Smoothing Points side menu. The amount of shift is calculated internally to enable
a smooth link and to minimize the effect on the unchanged portions. The
calculation uses a cubic polynomial for the horizontal amount and sine for the
vertical amount.
The value of the points mentioned above are usually nonintegers. That is, the
resulting horizontal coordinates of the points are not integers. The values at the
coordinates (integers) on the horizontal axis of the waveform data are sequentially
obtained using the interpolation you specified with the Interpolate side menu.
Quick Controls
To enable the Quick Edit mode, press the QUICK EDIT front–panel button, as
shown in Figure 3-25.
Figure 3-25: Controls for quick editing