User's Manual
Table Of Contents
- Title page
- Table of Contents
- General Safety Summary
- Preface
- Getting Started
- Operating Basics
- Reference
- Reference
- Menu Structures
- The Setup Menu Screen
- The Graphical Waveform Editor
- The Pattern Editor
- Quick Editing
- The Table Editor
- The Equation Editor
- The Sequence Editor
- The APPL Menu
- The UTILITY Window
- External Keyboards
- Setting General Purpose Knob Direction
- Formatting a Floppy Disk
- Displaying Disk Usage
- Screen Display Enable/Disable
- Focused Color
- Displaying Instrument Status
- Internal Clock (Date and Time)
- Resetting the Instrument
- Connecting to a GPIB Network
- Ethernet Networking
- Hardcopy
- Calibration and Diagnostics
- Upgrading the System Software
- Capturing Waveforms
- Waveform Programming Language
- Command Descriptions
- Programming Examples
- File Conversion
- File Management
- FG Mode
- Waveform Mixing Mode
- Synchronous Operation Mode (AWG710B only)
- Appendices
- Appendix A: Specifications (AWG710B)
- Appendix A: Specifications (AWG710)
- Appendix B: Performance Verification (AWG710B)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- External Clock Input and VCO Out Output Tests
- VCO OUT Output Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Synchronous Operation Tests
- Appendix B: Performance Verification (AWG710)
- Conventions
- Self Tests
- Performance Tests
- Operating Mode Tests
- Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
- Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
- Pulse Response Tests (Normal Out), (except option 02)
- Trigger Input Tests
- Event Input and Enhanced Mode Tests
- 1/4 Clock Frequency and 10 MHz Reference Input Tests
- Marker Output Tests
- Appendix C: Inspection and Cleaning
- Appendix D: Sample Waveforms
- Appendix E: File Transfer Interface Outline
- Appendix F: Miscellaneous
- Appendix G: Sequence File Text Format
- Index

The Setup Menu Screen
AWG710&AWG710B Arbitrary Waveform Generator User Manual 3-35
Extended Operation Displays the Extended Operation side menu to select four operation
modes AWG mode, FG mode, Waveform Mixing mode, and Synchronous
Operation mode.
Table 3-4: Status area
Item Description
Clock Displays the clock rate of an internal clock or an external clock. The clock
rate of an external clock is measured and displayed when external clock
use. The following message is displayed in addition to a numerical value.
PLL UNLOCKED: There is no Ref In signal when Clock Src is
Internal and Clock Ref is External.
NO SIGNAL: There is no Clock signal when Clock Src is External.
OUT OF RANGE: The clock rate of a external clock signal is out of
range when Clock Src is External.
NOT STABLE: The clock rate of a external clock signal is within
range but not stable when Clock Src is External.
Run Mode Displays the Run Mode selected on the Run Mode menu.
Instrument statusl The following state of a sequencer of operation is displayed.
Stopped: Output operation has stopped.
Running: Output operation is executing.
Waiting: Waiting for a trigger signal or an event signal where the
run mode is except Continuous.
Table 3-3: Setup bottom menu buttons
Bottom menu
button Description