Datasheet
Amplitude
Range (50 Ω load)
≤25 MHz
AFG1022 AFG1062
1 mV
p-p
to 10 V
p-p
1 mV
p-p
to 10 V
p-p
>25 MHz
- 1 mV
p-p
to 5 V
p-p
Range (Open circuit or high Z
load)
≤25 MHz
2 mV
p-p
to 20 V
p-p
2 mV
p-p
to 20 V
p-p
>25 MHz
-
2 mV
p-p
to 10 V
p-p
Accuracy ±(1% of setting +1 mV
p-p
), (1 kHz sine waveform, 0 V offset)
Resolution 1 mV
p-p
, 1 mV
rms
or 4 digits
Units V
p-p
, V
rms
Output impedance 50 Ω (typical)
Local impedance setting Selectable: 50 Ω, 1 Ω to 10.000 kΩ, High Z (adjusts displayed amplitude according to selected load impedance)
Isolation No floating ground, signal ground connected to chassis ground
Signal output protection Short-circuit tolerance, main output automatically disabled when over current
DC offset
Range ±(5 V
pk
– Amplitude
p-p
/2), 50 Ω load
±(10 V
pk
– Amplitude
p-p
/2), open circuit or high Z load
Accuracy ±(1% of |setting| + 1 mV + 0.5% of amplitude (V
p-p
))
Resolution 1 mV or 4 digits
Modulation
Modulation, sweeping, and burst modes are only available for channel 1 on the AFG1022.
The AFG1062 supports equal strong channels with modulation, sweeping, and burst modes.
Amplitude modulation
Carrier waveforms Sine, square, ramp, arbitrary, except DC and noise
Source Internal / external
Internal modulating
waveforms
Sine, square, ramp, noise, arbitrary
Internal AM frequency 2 mHz to 20 kHz
Depth 0.0% to 100.0%
Frequency modulation
Carrier waveforms Sine, square, ramp, arbitrary, except DC and noise
Source Internal / external
Internal modulating
waveforms
Sine, square, ramp, noise, arbitrary
Datasheet
General characteristics
4 www.tektronix.com