Datasheet
DC gain accuracy ±1.5% (±2.0% at 1mV/div), derated at 0.10%/°C above 30 °C
±3.0% for variable gain, derated 0.10%/°C above 30 °C
Offset accuracy ±(0.005 * |offset - position| + DC Balance)
DC balance 0.1 div with DC - 50Ω scope input impedance (50Ω BNC terminated)
Channel-to-channel isolation
(typical)
Any two channels at equal vertical scale ≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth
Random noise
Vertical scale setting 50 Ω, RMS
MDO4104C (all
configurations)
MDO40x4C (with option SA3
or SA6)
MDO40x4C (without option
SA3 or SA6)
1 mV/div 0.093 mV 0.084 mV 0.163 mV
100 mV/div 3.31 mV 2.37 mV 2.01 mV
1 V/div 24.27 mV 20.62 mV 20.51 mV
Offset range
Volts/div setting
Offset range
1 M Ω input 50 Ω input
1 mV/div to 50 mV/div ±1 V ±1 V
50.5 mV/div to 99.5 mV/div ±0.5 V ±0.5 V
100 mV/div to 500 mV/div ±10 V ±10 V
505 mV/div to 995 mV/div ±5 V ±5 V
1 V/div to 10 V/div ±100 V ±5 V
5.05 V/div to 10 V/div ±50 V NA
Horizontal system analog channels
Time base range
1 GHz models (without option
SA3 or SA6) and 1 GHz
models (with option SA3 or
SA6 with 2 channels enabled)
400 ps to 1000 s
≤ 500 MHz models and 1 GHz
models (with option SA3 or
SA6 and 4 channels enabled)
1 ns to 1000 s
Maximum duration at highest
sample rate (all/half channels)
1 GHz models (without option
SA3 or SA6) and 1 GHz
models (with option SA3 or
SA6 with 2 channels enabled)
8/4 ms
≤ 500 MHz models and 1 GHz
models (with option SA3 or
SA6 and 4 channels enabled)
8/8 ms
Time-base delay time range -10 divisions to 5000 s
MDO4000C Series Oscilloscope
Vertical system analog channels
www.tek.com 21