Mixed Domain Oscilloscopes MDO4000C Series Datasheet 2. Spectrum Analyzer (Optional) Frequency range of 9 kHz - 3 GHz or 9 KHz - 6 GHz Ultra-wide capture bandwidth ≥1 GHz Time-synchronized capture of spectrum analyzer with analog and digital acquisitions Frequency vs. time, amplitude vs. time, and phase vs. time waveforms 3.
Datasheet MSO/DPO2000B High-level description Commonly used for Analog Bandwidth MDO3000 Advanced Debug Features at an 6-in-1 integrated oscilloscope Affordable Price MDO4000C MSO/DPO5000B Performance 6-in-1 integrated oscilloscope with synchronized insights into analog, digital and spectral signals Exceptional Signal Fidelity with Advanced Analysis and Math Design and Debug Design and Debug Design and Debug Advanced Design and Debug Education EMI Troubleshooting EMI Troubleshooting USB Eth
MDO4000C Series Oscilloscope Typical applications Embedded design Discover and solve issues quickly by performing system level debug on mixed signal embedded systems including today's most common serial bus and wireless technologies. Power design Make reliable and repeatable voltage, current, and power measurements using automated power quality, switching loss, harmonics, ripple, modulation, and safe operating area measurements with the widest selection of power probes in an affordable solution.
Datasheet Triggering – Discovering a device fault is only the first step. Next, you must capture the event of interest to identify root cause. To enable this, the MDO4000C contains over 125 trigger combinations providing a complete set of triggers - including runt, logic, pulse width/glitch, setup and hold violation, serial packet, and parallel data - to help quickly locate your event of interest.
MDO4000C Series Oscilloscope Search step 1: You define what you would like to find. Search step 3: The Search Mark table provides a tabular view of each of the events found by the automated search. Each event is shown with a time stamp making timing measurements between events easy. Waveform analysis – Verifying that your prototype’s performance matches simulations and meets the project’s design goals requires analyzing its behavior.
Datasheet Standard features such as IRE and mV graticules, holdoff by fields, video polarity, and an Autoset smart enough to detect video signals, make these the easiest to use oscilloscopes on the market for video applications. And with high bandwidth and four analog inputs, the oscilloscope provides ample performance for analog and digital video use.
MDO4000C Series Oscilloscope Power quality measurement. Automated power measurements enable quick and accurate analysis of common power parameters. Limit-mask testing (Optional) – A common task during the development process is characterizing the behavior of certain signals in a system. One method, called limit testing, is to compare a tested signal to a known good or "golden" version of the same signal with user-defined vertical and horizontal tolerances.
Datasheet The highest amplitude peak is referred to as the reference marker and is shown in red. Marker readouts can be switched between Absolute and Delta readouts. When Delta is selected, marker readouts show each peak's delta frequency and delta amplitude from the reference marker. Two manual markers are also available for measuring non-peak portions of the spectrum. When enabled, the reference marker is attached to one of the manual markers, enabling delta measurements from anywhere in the spectrum.
MDO4000C Series Oscilloscope Advanced triggering with analog, digital and spectrum analyzer channels – In order to deal with the time-varying nature of modern RF applications, the MDO4000C Series provides a triggered acquisition system that is fully integrated with the analog, digital and spectrum analyzer channels.
Datasheet The MDO4000C, with its integrated oscilloscope, logic analyzer, and spectrum analyzer is the ultimate tool for debugging modern EMI issues. Many EMI problems are caused from events rooted in the time domain, such as clocks, power supplies, and serial data links. With its ability to provide time correlated views of analog, digital, and RF signals, the MDO4000C is the only instrument available that can discover the connection between time-domain events and offending spectral emissions.
MDO4000C Series Oscilloscope However, the power of the MDO4000C Series goes well beyond simply observing the frequency domain as you would on a spectrum analyzer. The real power is in its ability to correlate events in the frequency domain with the time domain phenomena that caused them. When both the spectrum analyzer and any analog or digital channels are on, the oscilloscope display is split into two views. The upper half of the display is a traditional oscilloscope view of the Time Domain.
Datasheet The integrated function generator provides output of predefined waveforms up to 50 MHz for sine, square, pulse, ramp/triangle, DC, noise, sin(x)/x (Sinc), Gaussian, Lorentz, exponential rise/fall, Haversine and cardiac. 3. Spectrum Time is moved another 160 μs to the right. At this point the spectrum shows that the PLL has actually overshot the correct frequency and gone all the way down to 2.3888 GHz. Waveform type selection in the integrated AFG.
MDO4000C Series Oscilloscope 4- Logic Analyzer (Optional) The logic analyzer (option MDO4MSO) provides 16 digital channels which are tightly integrated into the oscilloscope's user interface. This simplifies operation and makes it possible to solve mixed-signal issues easily. With color-coded digital waveform display, groups are created by simply placing digital channels together on the screen, allowing digital channels to be moved as a group.
Datasheet P6616 MSO probe – This unique probe design offers two eight-channel pods. Each channel ends with a probe tip featuring a recessed ground for simplified connection to the device under test. The coax on the first channel of each pod is colored blue making it easy to identify. The common ground uses an automotive-style connector making it easy to create custom grounds for connecting to the device under test.
MDO4000C Series Oscilloscope Serial bus technologies supported by the MDO4000C Technology Trigger, Decode, Search Order product I2C Yes DPO4EMBD SPI Yes DPO4EMBD Computer RS232/422/485, UART Yes DPO4COMP USB USB LS, FS, HS Yes (trigger on LS FS, HS) HS available only on 1 GHz models DPO4USB Yes DPO4ENET Embedded Search (serial triggering) – Serial triggering is very useful for isolating the event of interest, but once you’ve captured it and need to analyze the surrounding data, what do
Datasheet The MDO4000C Series Platform The embedded e*Scope ® capability enables fast control of the oscilloscope over a network connection through a standard web browser. Simply enter the IP address or network name of the oscilloscope and a web page will be served to the browser. Transfer and save settings, waveforms, measurements, and screen images or make live control changes to settings on the oscilloscope directly from the web browser. The MDO4000C Series is designed to make your work easier.
MDO4000C Series Oscilloscope TekVPI® probe interface. The TekVPI probe interface sets the standard for ease of use in probing. In addition to the secure, reliable connection that the interface provides, TekVPI probes feature status indicators and controls, as well as a probe menu button right on the comp box itself. This button brings up a probe menu on the oscilloscope display with all relevant settings and controls for the probe.
Datasheet 18 www.tek.
MDO4000C Series Oscilloscope www.tek.
Datasheet Specifications All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise. 1- Oscilloscope MDO4024C MDO4034C MDO4054C MDO4104C Analog channels 4 4 4 4 Analog channel bandwidth 200 MHz 350 MHz 500 MHz 1 GHz Rise time 1.75 ns 1 ns 700 ps 350 ps Sample rate (1 ch) 2.5 GS/s 2.5 GS/s 2.5 GS/s 5 GS/s Sample rate (2 ch) 2.5 GS/s 2.5 GS/s 2.
MDO4000C Series Oscilloscope Vertical system analog channels DC gain accuracy ±1.5% (±2.0% at 1mV/div), derated at 0.10%/°C above 30 °C ±3.0% for variable gain, derated 0.10%/°C above 30 °C Offset accuracy ±(0.005 * |offset - position| + DC Balance) DC balance 0.
Datasheet Horizontal system analog channels Channel-to-channel deskew range ±125 ns Time base accuracy ±5 ppm over any ≥1 ms interval Trigger system Trigger modes Auto, Normal, and Single Trigger coupling DC, AC, HF reject (attenuates >50 kHz), LF reject (attenuates <50 kHz), noise reject (reduces sensitivity) Trigger holdoff range 20 ns to 8 s Trigger sensitivity Internal DC coupled 1 mV/div to 4.98 mV/div 1.8 div 5 mV/div to 9.98 mV/div 0.6 div 10 mV/div to 19.98 mV/div 1.
MDO4000C Series Oscilloscope Trigger system Extended Video (optional) Trigger on 480p/60, 576p/50, 720p/30, 720p/50, 720p/60, 875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF, 1080p/25, 1080p/ 30, 1080p/50, 1080p/60, and custom bi-level and tri-level sync video standards. Custom bi-level and tri-level sync video standards. Parallel (requires option MDO4MSO) Trigger on a parallel bus data value. Parallel bus can be from 1 to 20 bits (from the digital and analog channels) in size.
Datasheet Waveform math Arithmetic Add, subtract, multiply, and divide waveforms. Math functions Integrate, differentiate, FFT FFT Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris. Spectrum math Add or subtract frequency-domain traces.
MDO4000C Series Oscilloscope Power measurements (optional, requires DPO4PWR) Power quality measurements VRMS, VCrest Factor, Frequency, IRMS, ICrest Factor, True Power, Apparent Power, Reactive Power, Power Factor, Phase Angle. Switching loss measurements Power loss Ton, Toff, Conduction, Total. Energy loss Ton, Toff, Conduction, Total. Harmonics THD-F, THD-R, RMS measurements. Graphical and table displays of harmonics. Test to IEC61000-3-2 Class A and MILSTD-1399, Section 300A.
Datasheet 2- Spectrum Analyzer (requires Option SA3 or SA6) Spectrum analyzer input Span 1 kHz - 3 GHz (models with option SA3) or 1 kHz - 6 GHz (models with option SA6) Span adjustable in a 1-2-5 sequence Variable resolution = 1% of the next span setting Resolution bandwidth range The resolution bandwidth range for windowing functions is as follows: Kaiser (default): 20 Hz - 200 MHz Rectangular: 10 Hz - 200 MHz Hamming: 10 Hz - 200 MHz Hanning: 10 Hz - 200 MHz Blackman-Harris: 20 Hz - 200 MHz Flat-top:
MDO4000C Series Oscilloscope 2- Spectrum Analyzer (requires Option SA3 or SA6) Spurious response 2nd and 3rd harmonic distortion (>100 MHz) < -60 dBc (< -60 dBc, typical), with auto settings on and signals 10 dB below reference level 2nd and 3rd harmonic distortion (9 kHz to 100 MHz ) < -57 dBc (< -65 dBc, typical), with auto settings on, signals 10 dB below reference level, and reference level ≤ -15 dBm 2nd order intermodulation distortion (>200 MHz) < -60 dBc (< -65 dBc, typical), with auto settings
Datasheet 2- Spectrum Analyzer (requires Option SA3 or SA6) Absolute amplitude accuracy (AAA) and channel response (CR), with TPA-N-PRE preamp attached AAA: ≤ ±0.5 dB (typical), 18 ⁰C - 28 ⁰C temperature range, 50 kHz to 6 GHz, either preamp state. AAA: ≤ ±2.0 dB (typical), 18 ⁰C - 28 ⁰C temperature range, 9 kHz to 50 kHz, either preamp state. AAA: ≤ ±2.3 dB (typical), over full operating range, either preamp state. CR: 0.
MDO4000C Series Oscilloscope 2- Spectrum Analyzer (requires Option SA3 or SA6) RF Power level trigger Frequency range Models with option SA3: 1 MHz to 3 GHz Models with option SA6: 1 MHz to 3.75 GHz; 2.75 GHz to 4.5 GHz, 3.5 GHz to 6.
Datasheet 3- Arbitrary Function Generator (requires Option MDO4AFG) Duty cycle 10% to 90% or 10 ns minimum pulse, whichever is larger cycle Duty cycle resolution 0.1% Pulse width minimum (typical) 10 ns Rise/fall time (typical) 5 ns (10% - 90%) Pulse width resolution 100 ps Overshoot (typical) < 2% for signal steps greater than 100 mV Asymmetry ±1% ±5 ns, at 50% duty cycle Jitter (TIE RMS) (typical) < 500 ps Ramp / Triangle Frequency range 0.
MDO4000C Series Oscilloscope 3- Arbitrary Function Generator (requires Option MDO4AFG) Repetition rate 0.1 Hz to 25 MHz Sample rate 250 MS/s Frequency accuracy Sine wave and ramp 130 ppm (frequency < 10 kHz) 50 ppm (frequency ≥ 10 kHz) Square wave and pulse 130 ppm (frequency < 10 kHz) 50 ppm (frequency ≥ 10 kHz) Resolution Amplitude accuracy 0.1 Hz or 4 digits, whichever is larger ±[ (1.5% of peak-to-peak amplitude setting) + (1.
Datasheet Horizontal system digital channels Maximum sample rate (Main) 500 MS/s (2 ns resolution) Maximum record length (Main) 20 M Maximum sample rate (MagniVu) 16.5 GS/s (60.6 ps resolution) Maximum record length (MagniVu 10k centered on the trigger Minimum detectable pulse width 1 ns Channel-to-channel skew (typical) 200 ps (typical) Maximum input toggle rate 500 MHz (Maximum frequency sine wave that can accurately be reproduced as a logic square wave.
MDO4000C Series Oscilloscope 5- Serial Protocol Analyzer (optional) USB: High speed 2 Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special Packet, Error. Token packet trigger - Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any Token, OUT, IN, and SETUP token types. Address can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular value, or inside or outside of a range.
Datasheet 6- Digital Voltmeter and Frequency Counter Source Channel 1, Channel 2, Channel 3, Channel 4 Measurement types AC RMS, DC, AC+DC RMS (reads out in volts or amps); Frequency Voltage accuracy ±(1.5% |reading - offset - position|) + (0.5% |(offset - position)|) + (0.
MDO4000C Series Oscilloscope Input-output ports USB 2.0 high-speed host port Supports USB mass storage devices and keyboard. Two ports on front and two ports on rear of instrument. USB 2.0 device port Rear-panel connector allows for communication/control of oscilloscope through USBTMC or GPIB (with a TEK-USB-488), and direct printing to all PictBridge-compatible printers. Printing Print PictBridge printer or to a printer that supports e-mail printing.
Datasheet Software OpenChoice® Desktop Enables fast and easy communication between a Windows PC and your oscilloscope using USB or LAN. Transfer and save settings, waveforms, measurements, and screen images. Included Word and Excel toolbars automate the transfer of acquisition data and screen images from the oscilloscope into Word and Excel for quick reporting or further analysis. Download from www.tek.com/software/downloads.
MDO4000C Series Oscilloscope EMC environment and safety Temperature Operating 0 ºC to +50 ºC (+32 ºF to +122 ºF) Nonoperating -30 ºC to +70 ºC (-22 ºF to +158 ºF) Humidity Operating High: 40 ºC to 50 ºC, 10% to 60% relative humidity, Low: 0 ºC to 40 ºC, 10% to 90% relative humidity Nonoperating High: 40 ºC to 60 ºC, 5% to 55% relative humidity, Low: 0 ºC to 40 ºC, 5% to 90% relative humidity Altitude Operating 3,000 meters (9,843 feet) Nonoperating 12,000 meters (39,370 feet) Regulatory CE mark
Datasheet Ordering information Step 1 Choose the MDO4000C base model MDO4000C family MDO4024C Mixed Domain Oscilloscope with (4) 200 MHz analog channels MDO4034C Mixed Domain Oscilloscope with (4) 350 MHz analog channels MDO4054C Mixed Domain Oscilloscope with (4) 500 MHz analog channels MDO4104C Mixed Domain Oscilloscope with (4) 1 GHz analog channels Standard accessories Probes ≤ 500 MHz models TPP0500B, 500 MHz bandwidth, 10X, 3.9 pF. One passive voltage probe per analog channel.
MDO4000C Series Oscilloscope Step 2 Configure your MDO4000C by adding instrument options Instrument options All MDO4000C Series instruments can be preconfigured from the factory with the following options: MDO4AFG Arbitrary function generator with 13 predefined waveforms and arbitrary waveform generation MDO4MSO 16 digital channels; includes P6616 digital probe and accessories SA3 Integrated spectrum analyzer with frequency range of 9 kHz to 3 GHz SA6 Integrated spectrum analyzer with frequency range
Datasheet Service options Tektronix offers a range of warranty and service plans to extend the life of your product and protect you from unplanned costs. Whether you want to protect yourself from accidental damage, or just save money on maintenance with a calibration plan, there is a service option available that meets your needs. Opt. C3 Calibration Service 3 Years Opt. C5 Calibration Service 5 Years Opt. D1 Calibration Data Report Opt. D3 Calibration Data Report 3 Years (with Opt. C3) Opt.
MDO4000C Series Oscilloscope DPO4COMP Computer Serial Triggering and Analysis Module. Enables triggering on packet-level information on RS-232/422/485/UART buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs - Any Ch1 - Ch4, any D0 - D15 Recommended Probing - RS-232/UART: Single ended; RS-422/485: Differential DPO4EMBD Embedded Serial Triggering and Analysis Module.
Datasheet TCP0150 20 MHz TekVPI® 150 Ampere AC/DC current probe TDP0500 500 MHz TekVPI® differential voltage probe with ±42 V differential input voltage TDP1000 1 GHz TekVPI® differential voltage probe with ±42 V differential input voltage TDP1500 1.5 GHz TekVPI® differential voltage probe with ±8.5 V differential input voltage TDP3500 3.5 GHz TekVPI® differential voltage probe with ±2 V differential input voltage THDP0200 ±1.
MDO4000C Series Oscilloscope Step 4 Add instrument upgrades in the future Instrument upgrades The MDO4000C Series products offer a number of ways to add functionality after the initial purchase. Listed below are the various product upgrades available and the method of upgrade used for each product. Free instrument options Digital Voltmeter and Frequency Counter Post-purchase instrument options MDO4AFG The following options are available free of charge when the MDO4000C product is registered at www.tek.
Datasheet Bandwidth upgrade options Instrument bandwidth can be upgraded on any MDO4000C Series product after initial purchase. Each upgrade product increases the analog bandwidth of the oscilloscope. Bandwidth upgrades are purchased based on the combination of the current bandwidth and the desired bandwidth and whether the current instrument contains an integrated spectrum analyzer. Bandwidth upgrade products include new analog probes if applicable.
MDO4000C Series Oscilloscope www.tek.
Datasheet ASEAN / Australasia (65) 6356 3900 Belgium 00800 2255 4835* Central East Europe and the Baltics +41 52 675 3777 Finland +41 52 675 3777 Hong Kong 400 820 5835 Japan 81 (3) 6714 3010 Middle East, Asia, and North Africa +41 52 675 3777 People's Republic of China 400 820 5835 Republic of Korea +822 6917 5084, 822 6917 5080 Spain 00800 2255 4835* Taiwan 886 (2) 2656 6688 Austria 00800 2255 4835* Brazil +55 (11) 3759 7627 Central Europe & Greece +41 52 675 3777 France 00800 2255 4835* India 000 800 6