User's Guide
Gen2 BLE Sensor Family User Guide T0007796_UG_Portable Version 0.2
TEKTELIC Communications Inc. Page 24 of 30
3 Operation, Alarms, and Management
3.1 Configuration
The Gen2 sensor variants support a full range of OTA configuration options. Specific technical
details are available in the corresponding TRM document for each functional grouping. All
configuration commands need to be sent OTA during the sensor’s DL Rx windows.
3.2 Default Configuration
Table 3-1 lists the default reporting behaviour for each functional grouping of the Gen2 sensor
variants. Reporting behaviour can be changed from default through OTA DL commands.
Table 3-1: Default Reporting Periods of Functional Groupings
Reported Data
SafeAlerts
Contact Tracing Devices
Battery Voltage
24 hours
24 hours
Discovered BLE devices
60 seconds (when button is
pressed)
N/A
Contact Data
N/A
15 minutes
Acceleration Vector
Disabled
N/A
MCU Temperature
Disabled
Disabled
3.3 RF LED Behaviour
See Figure 1-4 for the location and identification of the green and red Sensor RF LEDs. The boot
and join LED procedure is as follows.
1. Both LEDs will come on briefly when power is first applied.
2. After a small delay ( < 1 s) the LEDs will turn off and one of them will blink briefly.
a. If the green system LED blinks, then all health checks on the board passed.