Light sensitivity
Detection of weak light to typical work light conditions (5 lux
to 1000 lux)
2
Peak sensitivity at 550 nm
Pressure measurement accuracy
< ±1 hPa between 300 hPA and 1200 hPa
CO
2
concentration measurement
accuracy
±30 ppm +3% of reading between 400 ppm and 5000 ppm
Extended range ±10% of reading for an extended range of up
to 10000 ppm
3
Motion detection
Pyroelectric infrared sensor
Ceiling mount:
• X-angle: 104° (no mask)
• Y-angle: 104° (no mask)
Height: 3 m (no mask)
1.2.1 Transducer Details
1.2.2 Temperature/Humidity Sensor
The Room Sensor includes a combination temperature/humidity transducer from Sensirion
(SHTC3). It is a small footprint, very low power device. It features operation over I
2
C protocol
and operates from 0% to 100% RH and -40°C to 125°C with a typical accuracy of ±2% RH and
±0.2°C. The typical and maximum accuracies specified across the operating relative humidity
and temperature range of the sensor are shown in Figure 1-2 and Figure 1-3, respectively.
2
The sensor provides light intensity measurements, but they are not calibrated in lux. See the Technical Reference
Manual Invalid source specified. for more details.
3
No data available from manufacturer on performance outside the range of 15°C to 35°C and 0% to 80% RH.