User's Guide

Kona Enterprise Gateway T0007323_UG Version 1.3
TEKTELIC Communications Inc. Page 9 of 18
2 Installation
2.1 Overview
The Kona Enterprise Gateway has no internal field serviceable parts. The Gateway module
must only be opened by an approved TEKTELIC service center.
All installation practices must be in accordance with the local and national electrical codes.
Do not work on the system during periods of lightning activity.
The Kona Enterprise Gateway is considered permanently connected equipment. The
Protective Earth Ground connection (that is, the chassis ground) is always required.
Ensure the Kona Enterprise Gateway Protective Earth Ground connection is properly
terminated prior to the connection of any other interface.
The Kona Enterprise Gateway contains primary lightning surge suppression on the copper
Ethernet port, and the LoRa RF antenna port. The primary lightning protectors have the ability
to bridge the interface to chassis during over-voltages. Ensure that the Protective Earth
Ground connection is always in place.
An external inline surge protector must be applied to the External Cellular antenna port when
used.
Ensure that the Kona Enterprise Gateway is secured to eliminate any physical hazard to
people or property. The Gateway must be securely mounted according to the mounting
instructions prior to any cable connection and operation.
The Kona Enterprise Gateway does not contain a power disconnection device; a readily
accessible disconnection device must be incorporated external to the Kona Enterprise
Gateway.
The Kona Enterprise Gateway can only be powered either via PoE (Power-Over-Ethernet) or
passive POE combiner. Please note that when using a passive POE combiner, it is vital to use
a (minimum 10W) 48V power supply with Hiccup Mode Current Limiting.
Always ensure the Ethernet connection port and 3G/4G Modem SIM card access port are
properly sealed after installation or servicing.
The Kona Enterprise Gateway is intended to be installed in controlled area like tower or roof
top building with restricted access to general public. The installation and maintenance must
be performed by professional trained RF technician.