User's Guide

Kona Enterprise Gateway T0007323_UG Version 1.3
TEKTELIC Communications Inc. Page 11 of 18
2.4 Required Equipment for Installation
The Kona Enterprise Gateway is intended to be installed in controlled area like tower or roof
top building with restricted access to general public. The installation and maintenance must be
performed by professional trained RF technician.
The following tools are required to install the Kona Enterprise Gateway module:
1. A 6 point metric socket set and torque wrench drive.
2. Anti-oxidant compound (NO-OX-ID, Penetrox, Noalox, Ox-Gard or equivalent).
3. A small wire brush.
4. A clean cloth.
5. Weatherproofing tape kit for the RF connector (Scotch Wireless Weatherproofing Kit, WK-
101 recommended).
6. Supplied pole mounting accessories (shown in Figure 6) for pole mounting or appropriate
screws or bolts (four sized M6) with any required anchors according to the wall
construction for wall mounting.
2.5 Kona Enterprise Gateway Mounting
Kona Enterprise Gateway PoE must be mounted to a vertical pole or wall using the supplied
mounting hardware which attaches to the back of the module as illustrated in 5. The vertical
orientation is required for the GPS to function properly.