As soon as the specified magnetic pattern is applied to the Agriculture Sensor, the Agriculture
Sensor is reset and tries to join the network. See section 4.3 for the expected LED behaviour of
the Agriculture Sensor during the join process. It may take about 10 sec from the Agriculture
Sensor reset to seeing the LED activity showing join attempts. Therefore, as step 2 in the above
is completed, it takes about 13 seconds before observing the LED activity (provided that step 3
is respected).
Note that the specified magnetic pattern always triggers a module reset, even during normal
operation. Such a reset also activates an already in-DEEP-SLEEP module.
Figure 6 Agriculture Sensor Magnetic Reset/Wake-Up Pattern
The Agriculture Sensor can be put into DEEP SLEEP at any time by opening it up and pressing
the internal sleep button labeled as SW1 and located visibly on top of the Agriculture Sensor
PCBA. See Figure 7 below.
3 sec
> 3 sec
< 10 sec
< 3 sec< 1 sec
t
Pattern starts Pattern ends
Magnet Present
Magnet Absent
Simply bring magnet close, then
take it away, then bring it back
again, all at normal pace
Keep magnet attached for at least
3 sec but no longer than 10 sec
Magnet removed
Module reset (and
activated if in DEEP SLEEP)