User Manual
Table Of Contents
-Dati tecnici e caratteristiche soggetti a cambiamenti senza preavviso -Technische Daten und Eigenschaften mit Änderungen ohne Anzeige
-All the specifi cations are subject to change without notice - Données techniques et caracteristiques suiettes à des changements sans avis
89
SPEED - FASTER
17- ALARMS CHART
In case there is a malfunction, the machinery warns the user with a buzzer sound which can be muted by pressing the
INFO / ESC key.
The alarm state continues until the cause of the alarm is removed.
Below is the chart with the expected alarms in case of malfunction of the machinery:
ERROR MESSAGE DESCRIPTION POSSIBLE ROOT CAUSE USER SOLUTION
PRESERVATION IN PRO-
GRESS
Warning that the preservation
cycle is in progress, it lasts 24
hours
Cycle completed correctly
Remove the food from the blast
chiller and stop the cycle
FOOD PROBE NOT INSERT
The food probe is not inserted
Probe not inserted or malfun-
ctioning.
Insert the food probe. If the problem
persists, contact a qualifi ed techni-
cian.
DOOR OPEN
The door has been letf open Door open
Close the door. If the problem per-
sists, contact a qualifi ed technician.
DEFROSTING TIME
The defrosting cycle has been
stopped because of a timeout
or the cycle is longer than the
required time
The evaporator is still iced
Perform and additional defrosting
cycle or leave the machinery in
stand by for 12 hours with the door
open. If the problem persists, con-
tact a qualifi ed technician.
HIGH CONDENSER
Not enough heat dissipation at
the condenser
High room temperature, high
condenser temperature, con-
denser fan not working
Ventilate the room, clean the
condenser and do not block the air
vents. If the problem persists, con-
tact a qualifi ed technician.
BLACKOUT
Failure of the power supply
during one cycle
Failure of the power supply
during one cycle
Restore the machinery power supply
MAGNETOTHERMIC
Opening of the magnetothermic
switch contact
Failure or overload of the
compressor
Contact a qualifi ed technician
AIR PROBE
Malfunction or breakdown of
the air probe
Malfunction or breakdown of
the air probe
Contact a qualifi ed technician
EVAPORATOR PROBE
Malfunction or breakdown of
the evaporator probe
Malfunction or breakdown of
the evaporator probe Contact a qualifi ed technician
CONDENSER PROBE
Malfunction or breakdown of
the condenser probe
Malfunction or breakdown of
the condenser probe
Contact a qualifi ed technician
FOOD PROBE
Malfunction or breakdown of
the food probe
Malfunction or breakdown of
the food probe
Contact a qualifi ed technician