SPEED - FASTER
16.1 - I/O
The I/O submenu, also displayed during a duty cycle, allows the display of the following information:
- Air probe temperature : value expressed in °C
- Evaporator probe temperature: value expressed in °C
- Condenser probe temperature: value expressed in °C
- Food probe temperature: value expressed in °C
- D1 Door micro switch 1 : With value 1 active, with value 0 not active
- D2 Magnetothermic : With value 1 active, with value 0 not active
- U1 Compressor: With value 1 active, with value 0 not active
- U2 Fans: With value 1 active, with value 0 not active
- U3 Door frame resistor: With value 1 active, with value 0 not active
- U4 Sterilizer/Led/Alarm: With value 1 active, with value 0 not active
With the machinery in STOP mode, press the Info-ESC button
Select the submenu 1 with the UP and DOWN buttons
Press the CONFIRMATION button
Scroll with the UP and DOWN buttons to display all the values
Press the INFO-ESC button to go back to STOP mode.