Application Brochure
1 of 12 © A 664 - 12/09
- Application Brochure
Snow Detector & Melting Control 664
A 664
12/09
Application
The Snow Detector & Melting Control 664 is designed to control up to two zones in a snow melting system.
The control automatically adjusts the mixed supply water to the snow melting system by controlling up to two
boilers and a single mixing device. For mixing, the 664 can use a variable speed injection pump, a floating
action mixing valve or a 4-20 mA device. The snow melting system may be started manually or automatically
through the use of a Snow / Ice Sensor 090.
120 V (ac)
24 V (ac)
Melt Demand
Idle Demand
WWSD
Minimum
Maximum
Water
Melting
Snow Detector & Melting Control 664
Two Zone, Two Stage Boiler, Mixing
158033
Menu
Start Stop
Item
Features of the Snow Detector & Melting Control 664
Please refer to Essay E 005: Control Functions and Benefits for a detailed description of these features.
■ Boiler Differential (Automatic)
■ Boiler Minimum Supply
■ PID Staging
■ Equal Run Time Rotation
■ Fire Delay
■ Boiler Mass
■ Boiler Enable
■ Floating Action Output
■ Modulating Output
■ Variable Speed Output
■ Boiler Protection
■ System Protection
■ Snow / Ice Detection
■ Slab Protection
■ Viscosity Compensation
■ Slab Outdoor Reset
■ Snow Melting Setpoint
■ Snow Idling Setpoint
■ Warm Weather Cut Off
■ Cold Weather Cut Off
■ Pump / Integrated Exercising