Install Instructions
8 of 24
© 2016 tekmar 561
_
D - 11/16
Application 561-3
Electrical
-----------------------------------------------------------
B1
BP
PS
V1
S1
S2
T1
ZVC1
The WiFi Thermostat 561 operates a radiant floor heating system. The thermostat
uses both air and floor temperature sensors. The air temperature sensor can be
either built-in and/or external.
Mechanical
- - - ------ - - - ------ - ----- ------ - ----- ----------- - ----- -----
Legend
ZVC1
WiFi Thermostat 561
C
R
RH1
W1
AWAY
S1
S2
SEN
C
OM
Zone Valve Control or
Swit
ching Relay
C
R
AWAY
W
B1 = Boiler
BP = Boiler Pump
PS = System Pump
T1 = WiFi Thermostat 561
S1 = Floor Sensor 079
S2 = Optional Indoor Sensor 084
V1 = Zone Valve
ZVC1 = Zone Valve Control 304V or 306V