Installation Manual Thermostat 560 Compatible With • 1-stage heating • Supports optional floor sensor for radiant floor heating applications IOM-T-560
Table of Contents Important Safety Informati......................................................................................................................3 Installation..............................................................................................................................................4 Preparation........................................................................................................................................4 Removing The Thermostat Base...............
Important Safety Information It is your responsibility to ensure that this thermostat is safely installed according to all applicable codes and standards. tekmar is not responsible for damages resulting from improper installation and/ or maintenance. This is a safety-alert symbol. The safety alert symbol is shown alone or used with a signal word (DANGER, WARNING, or CAUTION), a pictorial and/or a safety message to identify hazards.
Installation Preparation Tools Required • Wire stripper • tekmar or jeweler screwdriver • Drill (for wall anchor) • Phillips head screwdriver • 3/16" drill bit (for wall anchor) Materials Required • 18 AWG LVT Solid Wire (Low Voltage Connections) Installation Location NOTICE Consider the following: • Interior Wall. • Keep dry. Avoid potential leakage onto the control. • Relative Humidity less than 90%. Non-condensing environment. • No exposure to extreme temperatures beyond 32-122°F (0-50°C).
Removing The Thermostat Base While holding the base section in one hand, pull the lower half of the display front towards you to pivot it away from the base. Moving The Thermostat To prevent the risk of personal injury and/or death, make sure power is not applied to the thermostat until it is fully installed and ready for final testing. All work must be done with power to the circuit being worked on turned off.
Application 560-1 The Thermostat 560 operates a radiant floor heating system. The thermostat uses the built-in air temperature sensor.
Application 560-2 The Thermostat 560 operates a radiant floor heating system based upon the floor temperature sensor. The built-in air sensor is disabled.
Application 560-3 Mechanical The Thermostat 560 operates a radiant floor heating system. The thermostat uses both air and floor temperature sensors. The air temperature sensor can be either built-in and/or external.
Application 560-4 Mechanical The Thermostat 560 operates a baseboard/radiator using an air temperature sensor. The air temperature sensor can be either built-in and/or external.
Sequence of Operation Heating Operation The Heat On symbol is shown on the display when the thermostat is heating. Heating for freeze protection is provided whenever the air or floor temperature falls below 40°F (4.5°C), regardless of operating mode. Regular Heating W1 relay is on when the air temperature falls 1.5°F (1°C) below the Heat To setting. When the temperature reaches the Heat To setting, the relay turns off.
User Interface After 60 seconds of inactivity, the thermostat home screen displays only the time and the temperature.
User Settings Away Use the Away setting to save energy when the building is unoccupied Home / Away Operates normally At Home Operates using the Away temperature selected in the Setup menu • The Away temperature can be adjusted in the Setup / Temps menu. Away Save Info Schedule Schedule Current group of program days. Early Start anticipates the time required to heat a room and starts early.
Display Setting Temperature units Select °F or °C. ENERGY USE View the number of hours the heating or cooling has operated either daily or monthly. Range Default °F or °C °F 0 to 24 (daily) 0 to 744 (monthly) 0 hours Daily Usage Today Yesterday Tue Mon Sun Sat Fri 0 hrs 0 hrs 0 hrs 0 hrs 0 hrs 0 hrs 0 hrs View each day's run time for heating. Toggle between Daily and Monthly Usage. Monthly Usage Setting BRIGHTNESS ACTIVE Select the brightness when touching the screen.
Time TIME & DATE Aug 25 2016 1 30 PM OPTIONS The time and date is manually set by highlighting a field and then using the or buttons. Choose from the time options listed below. Setting TIME FORMAT Select the time format. DAYLIGHT SAVING TIME Select the brightness when not in use.
Installer Settings Setup The Setup menu contains five sub-menus that determine how the thermostat operates. The Access Level setting in the Toolbox menu determines how many settings are available to the user. SETUP MENU TOOLBOX TEMP SENSORS ALERTS Press back to return to the main Settings menu. RELAYS Setup - Toolbox Setting ERROR Displays any error messages. ACCESS LEVEL Select between user and installer access levels. User access level restricts access in the Setup Menu.
Setup - Temp Setting Range Default Screen Page 1 FLOOR MIN Select the floor temperature minimum. Applies when there is both floor and an air sensors and when no schedule is set. FLOOR MIN - WAKE Select the floor temperature while in the wake schedule. Applies when there is both a floor and an air sensor. FLOOR MIN - LEAVE Select the floor temperature while in the leave schedule. Applies when there is both a floor and an air sensor.
Setup - Sensors Setting SENSOR 1 Select the type of sensor connected to S1 and Com wiring terminals. SENSOR 2 Select the type of sensor connected to S2 and Com wiring terminals. INTERNAL ROOM SENSOR Select if the internal room temperature sensor is on or off. Only available when Sensor 1 or 2 is set to read a room or floor sensor. ROOM OFFSET Select if the internal room temperature sensor is on or off. Only available when Sensor 1 or 2 is set to read a room or floor sensor.
Error Messages Error icon will appear on the home screen when an error is present. Description MEMORY ERROR The thermostat memory settings are corrupted. To clear, load the factory defaults in the Toolbox menu. The thermostat will not operate any heating equipment while this error message is present. INTERNAL ROOM SENSOR FAULT Due to an open or short circuit, the thermostat is unable to read the internal room temperature sensor.
Technical Data THERMOSTAT 560 ONE STAGE HEAT Literature ES-T-560, IOM-T-560, 560_J, UserManual-T-560 Control Microprocessor control. This is not a safety (limit) control. Packaged weight 0.6 lb.
Warranty Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any tekmar product (“Product”), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same. The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer’s pass-through warranty which the Purchaser is authorized to pass through to its customers.