Install Instructions

© 2015 554_D - 02/15
37 of 44
A Watts Water Technologies Company
Recommendation on How to Use Scenes
-----------------------------
Deciding how to use scenes depends on the needs and lifestyle of the customer using
the building.
Multi-Tenant Apartments
Scenes should be disabled (None) in multi-tenant buildings where each occupant has
differing heating requirements.
Residential Homes
Some residential customers may not require scenes. In that case, scenes can be
disabled (None). Homeowners who wish to save on energy costs should consider using
the Away scene to save energy while they are away from their property (example, on
vacation or on holidays).
The use of the Guest scene is useful in residential applications where a number of spare
bedrooms are occupied infrequent. Each spare bedroom would be set up to operate
on the Guest scene. The remaining thermostats can be set up to operate on the None,
Away or All scene configuration. Normally, the spare bedrooms would operate at the
moon temperature settings. When guests arrive, scene 5 can be activated through
a User Switch or Gateway. The spare bedroom then operates at the temperature
settings or operates on a programmable schedule if a schedule has been set up. When
guests depart, the scene can be changed back to scene 1 and the spare bedrooms
resume operation at the temperature settings.
Commercial Buildings
Commercial buildings are typically in use on a predictable schedule and normally can
operate in scene 1. In order to accommodate staff working overtime or cleaning staff,
a 3-hour or 8-hour temporary override is available when installed in conjunction with
a User Switch or Gateway. In these cases, the thermostats should be set up to use
the All scene configuration. At the touch of a button, the whole building changes from
operating on a programmable schedule (typically at the temperature setting when
not occupied) to operating at the temperature settings for 3 hours (scene 6) or 8
hours (scene 8). After the timer counts down and expires, the scene changes back to
the previous scene.
Secondary Temperature Display
This thermostat can display the outdoor, floor, or room heating and cooling temperature
settings in the smaller number area at the top right of the screen. To toggle the item
currently displayed, touch the secondary temperature. Display of the floor or outdoor
temperature requires a connection to an outdoor or floor temperature sensor, or the
thermostat is connected to a tekmarNet
®
system that includes an outdoor sensor. The
reading of the outdoor sensor connected directly to the thermostat takes precedence
over any outdoor sensor reading available on the tekmarNet
®
system.
or or or