Application Brochure

© 2013 553_A - 04/13
4 of 16
A Watts Water Technologies Company
2 Heat / 1 Fan / Humidification
553_A-2
Description
The 553 operates a radiant floor as the first stage of heat and a hydronic fan coil as the
second stage of heat. The fan operates with the heating system or independently for
ventilation. The thermostat can operate an optional humidifier to maintain a minimum
relative humidity setting. An optional coil sensor allows the fan coil to warm up to a
minimum temperature prior to turning on the fan.
Setup Menu Essential
Setting
Sensor 1 COIL
Y Relay HUM
W Term HRF
ACC Relay W2
W2 Term COIL
G / O Relay FAN
ACC
Y
G
W
Outdoor
Sensor
070
553
Humidifier
Fan Coil
Fan
Boiler
Radiant Floor
Coil Sensor 082
Coil Sensor 082
Wiring
Center
House
Control
*
Alternate humidifier locations