Installation and Operation Manual
8 of 40© 2011 D 552 - 08/11
Mounting the Thermostat
Push the thermostat front onto the
thermostat base. Installation is now
complete.
Thermostat
Front
Push
Thermostat
Base
Switch Settings
The thermostats’s exterior can be cleaned using a damp cloth. Moisten the cloth
with water and wring out prior to wiping the control. Do not use solvents or cleaning
solutions.
Cleaning the Thermostat
Switch
Position
Action
1
ON
LOCK ACCESS LEVEL
Thermostat is locally locked and the access level cannot be changed.
Set to Lock when installation has been completed.
OFF
UNLOCK ACCESS LEVEL
Thermostat is unlocked and the access level may be changed. Go to
the Toolbox menu to change the access level. Set to Unlock during
the installation process.
Note: tekmarNet
®
system controls include a Global Lock that locks all
connected thermostats. Set the tekmarNet
®
system control to unlock
to allow access level adjustment on all connected thermostats.
tNt 552
One Stage Heat
Mmm YYYY
Lot # 12345
Meets Class B:
Canadian ICES
FCC Part 15
Power: 24 V ±10% 50/60 Hz 1.7 VA
Relay: 24 V (ac) 2 A
1051-03
Switch Settings:
Use at least 75°C conductors
For instructions see brochure
Designed and
assembled in Canada
Setback
Scene
None
ON
Cool Master 1
Off
Unlock
123
/
tekmarNet
Thermostat 552
One Stage Heat
Mmm YYYY
Lot # 12345
Meets Class B: ICES & FCC Part 15
Power: tN2 or 24 V (ac) ±10% 1.8 VA
Relay: 24 V (ac) 2 A
1051-03
Switch
Settings
www.tekmarcontrols.com
Designed and assembled in Canada
Lock
Unused
Unlock
/
ON
1
2
Back of
Thermostat