Quick Setup Guide

© 2013 518_Q - 03/13
2 of 8
A Watts Water Technologies Company
3
1
/4
(83 mm)
Stud
Gang
Box
Thermostat
Front
Thermostat
Base
Adapter Plate 012
4. Installation to Gang Box
5. Wiring
C
518
R Rh W1 S1 Com
No Power
C
518
R Rh W1 S1 Com
No Power
Zone
Valve
24 V
LN
R C
Optional
Slab Sensor 079
Install field
jumper wire
R to Rh
6. User Interface