Submittal Sheet

Job __________________________
Designer ______________________
Contact _______________________
www.tekmarcontrols.com  of 2 © 20 C 36 - 0/


0/
HVAC Systems
Replaces: New

Front View
Side View
2–7/8
(72 mm)
1/2” Knock-out
(x 5 back) (x 5 bottom)
Mounting Base
CL
1/2”
(13 mm)
7/8
(23 mm)
65/8
(170 mm)
7–5/8
(193 mm)
1–7/8” (49 mm)
1/2”
(14 mm)
Ø 3/16” (5 mm)

------------
Outdoor Temperature Reset
Indoor Temperature Feedback (with
optional indoor sensor)
Warm Weather Shut Down
Boiler control
Automatic Boiler Differential

----------------
Variable speed pump control
Quick setup for easy installation and
programming of control
User comfort adjustment to increase or
decrease building space temperature
Advanced settings to fine-tune building
requirements
Powered mixing system pump output
Test sequence to ensure proper
component operation
Setback input for energy savings
20 V (ac) power supply
CSA C US certified (approved to applicable
UL standards)

-----------------------------------------------------
The Mixing Control 36is designed to operate a mixing pump using outdoor reset. It can be used in applications ranging from in-floor
radiant to commercial baseboard systems for boiler protection with full reset. This control regulates a single heating water temperature
through outdoor reset. It provides mixing by speeding up or slowing down a single permanent capacitor (standard wet rotor) circulator,
and provides control of the mix system pump.

N / A

Variable Speed

Signal wiring must be
rated at least 300 V.
Use supply wires
suitable for 120°F
(50°C) above ambient
L N Pmp N Pmp N Sw
2
Sys Var
UnO Com Boil Mix Com Out Indr
3 5 74
6
8
9 0
2 3
4
5 6
7
Mixing Power Boiler
Demand
Advanced
Installer
Boiler Sensor
Supply
30% Enable
10% Enable
Return
Item
Test
Terminal
Unit
10 30 50 70 90
% Out
Mixing
Demand
Made in Canada by
tekmar Control Systems Ltd.
Power: 120 V ±10% 50/60 Hz 1650 VA
Variable Pump: 240 V (ac) 2.4 A 1/6 hp, fuse T2.5 A
Relays: 240 V (ac) 10 A 1/3 hp, pilot duty 240 VA
Demand: 20 to 260 V (ac) 2 VA
H11888
To increase or decrease the
building temperature.
• Press the Item, , buttons
simultaneously for 1 sec. to
enter the ADJUST menu
• Use the, , buttons to adjust
the ROOM setting
Display defaults back to VIEW
menu after 20 sec.
ROOM
-
Set to desired room temp.
OUTDR DSGN
-
Set to coldest (design)
outdoor temp.
Terminal Unit Set to
High Mass Radiant ------- 1
Low Mass Radiant ------- 2
Fan Coil ------------------ 3
Convector ---------------- 4
Radiator ------------------ 5
Baseboard --------------- 6
Refer to brochure for more information

Variable Speed
Literature D36, A36, D00, D070, E02
Control Microprocessor control. This is not a safety (limit) control
Packaged weight 3.0 lb. (380 g)
Dimensions 6-5/8” H x 7-9/6” W x 2-3/6” D (70 x 93 x 72 mm)
Enclosure Blue PVC plastic, NEMA type 
Approvals
CSA C US, meets class B: ICES & FCC Part 5
Ambient conditions
Indoor use only, 32 to 04°F (0 to 40°C), RH ≤90% Non-
condensing
Power supply 20 V (ac) ±0%, 50/60 Hz, 650 VA
Variable pump 20 V (ac) 2.4 A (FLA) 5 A (LRA), fuse T2.5 A 250 V
Relays 240 V (ac) 0 A /3 hp
Demand 20 to 260 V (ac) 2 VA
Sensors NTC thermistor, 0 kΩ @ 77°F (25°C ±0.2°C) ß=3892
Included Outdoor Sensor 070 and 2 of Universal Sensor 082
Optional tekmar type #: 033, 076, 077, 084
Warranty Limited 3 Year (See D36 for full warranty)

Summary of content (2 pages)