Wiring Brochure

W 325
12/08
Zone Expansion Module 325
- Wiring Brochure
1 of 12 © 2008 W 325 - 12/08
N
Zone Group
89 90
Pmp C
tN4
Meets Class B:
Canadian ICES &
FCC Part 15
5 A (max)
Zone Expansion Module 325
tektra 998-01
Relay Rating: 115 V (ac) 5 A
24 V (ac) Fuse: T2.5 A 250 V
Power
Zone Group Pump C
H7001B
Zone C1
Zone C2
Zone C3
Zone C4
Zone C5
Zone C6
51 52 53 54 55 56 57 58 59 60 61 62
CCWWRRtN4 tN4 C WRtN4
tNt Zone C1 tNt Zone C2 tNt Zone C3
63 64 65 66
67 68 69 70 71 72 73 74
CCWWRRtN4 tN4 C WRtN4
tNt Zone C4 tNt Zone C5 tNt Zone C6
75 76
tN4C
Zn Grp C
C2
C3
On/Off
Zone Group
Pump C Delay
Zone Group
Pump C
C4
C5
C6
C5
C6
C1
C1
C3
C2
C4
Limited power available, see wiring brochure
77 78 79 80 81 82 83 84 85 86 87 88
Zone C1 Zone C2 Zone C3 Zone C4 Zone C5 Zone C6
C
Vlv
C
Vlv
C
Vlv
C
Vlv
C
Vlv
C
Vlv
Made in Canada
Information
Brochure
Choose controls
to match
application
1
Application
Brochure
Design your
mechanical
applications
2
Rough-in
Wiring
Rough-in
wiring
instructions
3
Wiring
Brochure
Wiring and
installation of
specific control
4
Job
Record
Record settings &
wiring details for
future reference
6
Data
Brochure
Control settings
and sequence of
operation
5
Overview
tekmar wiring Enclosure (not included)
tekmar Zone Manager
The following wiring brochure describes how to wire the tekmar Zone Expansion Module 325. The 325 is to be installed
in an enclosure together with a tekmar Zone Manager. The 325 controls up to six tekmarNet
®
4 (tN4) thermostats, six
24 V (ac) zone valves, and one 115 V (ac) Zone Group Pump. The wiring of tekmarNet
®
4 (tN4) components is simple
and cost effective.