Zoning
Replaces: 10/16
Switching Relay 306P
Installation & Operation Manual
RoomResponse
TM
signal
Compatible with all 24 V(ac) thermostats
Unlimited zone expansion
Zone priority
Priority override
Pump exercising
Post purge
LED for each zone, priority, end switch and RoomResponse
TM
Away signal shared between thermostats
Four ground screws
Top, bottom and back conduit knockouts
Fuses protect transformers and pumps
Two spare fuses included
CSA approved
Introduction
The Switching Relay
306
P connects up to six thermostats and operates circulators to provide heating to a zoned hydronic
heating system. Zone 1 has optional priority over zones 2 through 6 and can be used to provide heat to an indirect
domestic hot water tank. The 306P includes optional exercising to prevent circulator seizure when not in use, and optional
post purge operation of the last operating zone to maximize energy savings. The 306P provides a RoomResponse
TM
signal to modulating-condensing boilers to optimize comfort while improving boiler efficiency.
H3021A
Switching Relay 306P
Six Zones with Priority
RoomResponse
TM
Power
Priority
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6