Zoning
Replaces: 10/16
Switching Relay 304P
Installation & Operation Manual
RoomResponse
TM
signal
Compatible with all low voltage thermostats
Unlimited zone expansion
Zone priority
Priority override
Pump exercising
Post purge
LED for each zone, priority, end switch and RoomResponse
TM
Away signal shared between tekmar thermostats
Four ground screws
Top, bottom and back conduit knockouts
Fuses protect transformers and pumps
Two spare fuses included
CSA approved
Introduction
The Switching Relay
304
P connects up to four thermostats and operates circulators to provide heating to a zoned hydronic
heating system. Zone 1 has optional priority over zones 2 through 4 and can be used to provide heat to an indirect
domestic hot water tank. The 304P includes optional exercising to prevent circulator seizure when not in use, and optional
post purge operation of the last operating zone to maximize energy savings. The 304P provides a RoomResponse
TM
signal to modulating-condensing boilers to optimize comfort while improving boiler efficiency.
RoomResponse
TM
Power
Priority
Zone 1 Zone 2 Zone 3 Zone 4
Switching Relay 304P
Four Zones with Priority
H3020A
Features