S e n t r y 6140 U s e r M A N U A L Tip Flow Monitor
Copyrights © 2013 TeeJet Technologies. All rights reserved. No part of this document or the computer programs described in it may be reproduced, copied, photocopied, translated, or reduced in any form or by any means, electronic or machine readable, recording or otherwise, without prior written consent from TeeJet Technologies. Trademarks Unless otherwise noted, all other brand or product names are trademarks or registered trademarks of their respective companies or organizations.
Sentry 6140 Tip Flow Monitor Table of Contents Components 2 Boom Series Harness Connection................................................................................................................................................................... 5 SYSTEM COMPONENTS 6 Sentry 6140 Console.............................................................................................................................................................................................
Sentry 6140 Tip Flow Monitor Components Unpack the installation kit and identify the required parts for your installation. Item Part Number Description Quantity A 75-30100 Sentry 6140 Console........................................................................................................................................................1 B 78-05101 Tip Flow Monitor Interface (TFMI).................................................................................................................
Sentry 6140 Tip Flow Monitor Item Part # Description E 45-10142 Boom Interface Module (BIM) Harness (Actual harness may be machine specific.) F 45-05857: 3′/1 m, 45-05858: 6′/1.8 m, 45-05859: 12′/3.6 m, 45-05864: 35′/10.7 m Harness to Tip Sensor Interface Extension Cable F 45-05900: 5′/1.
Sentry 6140 Tip Flow Monitor Figure 1: System Diagram 75-30100 Sentry 6140 Console 45-05900: 5′/1.5 m 45-05901: 10′/3 m 45-05902: 20′/6 m 45-05903: 40′/12 m Console to TFMI Harness Extension Cable 401-0016 Battery Adapter 45-10142 BIM Harness 45-05856 Terminator, End (Male) 45-10148 TFMI Harness 75-05104 Tip Sensor Interface 78-05101 Tip Flow Monitor Interface (TFMI) 45-05857: 3′/1 m 45-05858: 6′/1.8 m 45-05859: 12′/3.6 m 45-05864: 35′/10.
Sentry 6140 Tip Flow Monitor Boom Series Harness Connection With each machine having a different possible switchbox configuration, it is impossible to specify the exact location to T-Tap into the valve harness. However, the following guidelines may provide some assistance in completing the installation. 1. Identify boom section cable that runs from the Boom Switchbox to the boom valves. 2. Use a T-Tap (or similar product) to connect into the signal wire.
Sentry 6140 Tip Flow Monitor SYSTEM COMPONENTS If there are questions concerning the installation of the Sentry 6140 system on this vehicle, or due to the changes in component specifications the parts supplied in the kit are not exactly as presented in this document, please contact your dealer or TeeJet Customer service representative for clarification before installation. TeeJet Technologies is not responsible for misuse or incorrect installation of the system.
Sentry 6140 Tip Flow Monitor Figure 7: Nozzle Body with Flow Meter Assembly Flow Meter Assembly The flow meter gasket has two different sides. The side with the larger center is to be inserted towards the sensor or inside the flow meter. Nozzle Body Figure 5: Flow Meter and Gasket Flow Meter Flow Meter Nozzle Body End Cap Gasket Figure 6: Gasket Detail Figure 8: Sensor & Clips Clips Towards flow meter Sensor Kit Assembly 1. 2. 3. 4. 5. 6. 7. 8. 9. Remove end cap from nozzle body.
Sentry 6140 Tip Flow Monitor Power Slide the POWER SWITCH to power on or off the console. Figure 12: Home Screen On power up the console detects the number of Tip Sensor Interfaces (TSI) (H or I) on the boom and displays the status of the sensors and the system. The LED’s on each TSI are turned on and go off as each is detected and given their unique address. Boom Status The addresses start at #1 and continue across the boom.
Sentry 6140 Tip Flow Monitor Setup If there are questions concerning the setup of the Sentry 6140, please contact your dealer or TeeJet Customer service representative for clarification before operation. TeeJet Technologies is not responsible for misuse or incorrect operation of the system.
Sentry 6140 Tip Flow Monitor Display Brightness Sets the brightness level of the display. Range is 5% to 100% in 5% increments. 1. Press the MINUS/PLUS buttons 2. Press ►NEXT PAGE button to adjust the brightness. to proceed to Master Sound. ►PREVIOUS PAGE button Off Beep. to go back to Boom Section On/ Tip Alarm Percentage Sets the error reporting range for the tip sensors. If the flow rate of an individual tip falls below, or rises above this range, the console will generate an alarm.
Sentry 6140 Tip Flow Monitor Number of Sections Figure 21: Tips per Section Select the number of boom sections. The sections are numbered from left to right while standing in the forward facing direction of the machine and begin at the Start Terminator. Range is 1 to 15 sections. 1. Press the MINUS/PLUS buttons boom sections. 2. Press ►NEXT PAGE button Section. to adjust the number of to proceed to Number of Tips per ►PREVIOUS PAGE button to go back to Tip Alarm Delay.
Sentry 6140 Tip Flow Monitor Tip Balance Balancing the tips is required for the system to compare and monitor individual tips. The system will scan all the tips to get the flow rate. The flow rate of each tip must be within the tip balance percentage range of the average flow rate in order to balance successfully. If any tip is outside this range, an error will be generated, and the user will need to inspect the tip.
Sentry 6140 Tip Flow Monitor Operation After the tips are balanced, the user can enter Operation mode. The system will monitor all the tips and their the flow rate if their respective boom section is turned on. The flow rate of each tip must be within the percentage range (entered in the Setup mode). If any tip is outside this range, an error will be generated, and the user will need to inspect the tip that is at fault.
S eU n t r y 6 1 4 0 s e r M a n u a l Identifying Plugged Spray Tips Has Never Been Easier Worn, plugged or partially blocked spray tips can have a significant impact on the quality of your spraying job. Streaks in the field caused by misapplication can result in yield reductions, increased weed pressure and the need to re-apply – all of which can be costly. The Sentry 6140 Tip Flow Monitor provides a simple, reliable solution to this age-old problem.